6.6) Errors/Malfunctions

These appear on the display during operation, combined with a beep to notify the operator of
procedural or operational errors.
Message
ERROR
001
002
003
004
6.7) Return to original default settings / fi rmware version
Select screen 10 from the "main menu" (Ref. to section 6.1), to return the pump to its default set-
ting hold the finger on the button (9) until a confirmation "beep" is heard.
RESET
The RESET screen also shows the fi rmware version of the control board.
SW:S1J76202
Error description
In CUTTING mode:
The cutting phase has been intention-
ally interrupted by the operator.
The pump has not developped the
pressure needed to cut the cable
In CRIMPING mode:
Oil discharge is activated before wait-
ing for the motor to be automatically
switched off
.
The pump has been started without the
fl exible hose connected or the hose is
not correctly connected.
Abnormal power consumption of the
motor.
The pump stops.
Output voltage of the pressure trans-
mitter is out of the pre-set range.
The pump stops and doesn't re-start.
Failure to reach the set pressure within
120 seconds of continuous operation
of the pump.
Overcharging of the battery with pro-
tection tripping.
The pump stops.
S
olution
In order to reset the alarm, press the pump
button on the radio control once for 2
seconds.
Repeat the cycle by holding the pump button
until the motor switches off automatically.
Repeat the crimping cycle, keeping the
pump button pressed down until the motor
switches off automatically.
In order to reset the alarm press the release
button, connect the fl exible hose or check
the correct connection to the pump.
Remove and re-insert the battery, then re-
start the pump.
If the error occurs frequently, contact
Cembre.
Remove and re-insert the battery, if the error
occurs, contact Cembre.
Repeat the work cycle; if the error occurs
frequently, contact Cembre.
Remove and re-insert the battery, then re-
start the pump.
If the error occurs frequently, contact
Cembre.