Cembre B68M-P18-KV-RC1 Operation And Maintenance Instruction Manual page 10

Electro-hydraulic battery pump radio controlled
Table of Contents

Advertisement

With the battery inserted in the pump, the remaining battery life
can also be checked on the display, via touch button selection
(Ref. to section 5).
The display alongside indicates that the battery is low and the pump
will not start (Ref. to section 6.5).
The approximate time to fully recharge a CB1870L battery is about
50 minutes.
 (E) Shoulder Strap: allows for easy transportation of the pump when connected to the rings
(2) on the pump.
It can also be used to secure the pump to the ladder in the manhole or to the manhole guard.
 (F) Radio Remote Control RRC1: allows users to control the pump from a safe distance.
(Ref. to section 2 for further details).
 (G) Portable hydraulic high capacity pump: driven by an 18 V battery powered electric motor.
An Electronic Pressure Sensor (EPS) ensures precision and repeatability of the work cycles and
a maximum pressure valve to ensure maximum operator safety.
The memory card integrated into the pump allows the storage of the data relating to previous
operating cycles.
The default settings of the pump are:
Operating mode: CUTTING (Ref. to section 6.2 to choose CRIMPING operating mode).
Oil release mode: SMART (Ref. to section 6.3 for further details).
Pump control mode: RADIO ON, enables the radio remote control (Ref. to section 6.4 for further
details).
Main components (Ref. to Fig. 2):
1 - OIL FIL LER CAP: for accessing the pump's oil tank.
2 - STRAP FASTENING RING: to attach the shoulder strap and transport the pump.
It can be used to hang the radio control before the storage of the pump.
3 - BATTERY RELEASE DEVICE: to lock/unlock the battery, press the button (3) and push the battery
downward to unlock it (Ref. to Fig. 4). Insert a battery from the bottom by sliding it into the side
guides until it locks.
4 - LED INDICATOR: to visually indicate to the operator the progress and the conclusion of the cut-
ting operation or to notify the operator of procedural or operational errors.
5 - BUZZER: synchronized with the LED indicator to indicate audibly the operation in progress or
to notify the operator of procedural or operational errors.
6 - RADIO RECEIVER BOX: includes the radio receiver of the remote control.
max.
min.
BATTERY
BATTERY
BATTERY
10