GX30
2. Apply 4 V using a stabilized power supply and turn on the handset.
3. Start RF test tool.
4. Select a COM port to which Data Cable is connected. (Figure 60)
5. Press the "Initialize & Read Data" button. (Figure 60)
6. Figure 61 appears (wait a few seconds).
7. Click "OK" to proceed.