2

Product Specific Information

A. Appliance Certification
MODELS: QFI30FB-IFT, QFI35FB-IFT,
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vent Heater
STANDARD: ANSI Z21.88-2017 • CSA 2.33-2017
This product is listed to ANSI standards for "Vented Gas
Fireplace Heaters" and applicable sections of "Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles", and "Gas Fired Appliances for
Use at High Altitudes".
Quadra-Fire gas inserts are designed for installations into
solid fuel masonry or factory built fireplaces that have been
installed in accordance with the National, Provincial, State
and local building codes. Fireplaces are to be constructed
of non-combustible materials and, in the absence of local
or regional codes, meet criteria of NFPA 211. No additional
outside air source is required.
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
B. Glass Specifications
This appliance is equipped with 5 mm ceramic glass with
an anti-reflective coating. Replace glass only with glass
with identical specifications. Please contact your dealer
for replacement glass.
6
Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Owner's Manual • 2555-981 Rev. B • 6/18
C. BTU Specifications
Models
(U.S. or Canada)
QFI30FB-IFT
(0-2000 FT)
(NG)
QFI30FB-IFT
(0-2000 FT)
(Propane)
QFI35FB-IFT
(0-2000 FT)
(NG)
QFI35FB-IFT
(0-2000 FT))
(Propane)
Maximum
Minimum
Orifice
Input
Input
Size
BTU/h
BTU/h
(DMS)
36,000
18,500
33
36,000
19,000
50
40,000
20,000
31
38,000
19,000
49