Summary of Contents for AcraDyne ABG Series

  • Page 1 Operation Service Manual ABG Series Battery Powered Nutrunners...
  • Page 2: Table Of Contents

    Operating the AcraDyne ABG Nutrunner operation or maintenance. The manual must be available and Starting accessible at the location of the AcraDyne tools/devices. This 4.1.1 Remove, Charge, Insert, or Change operating and maintenance manual refers exclusively to the Li-Ion Battery Pack AcraDyne ABG Battery-Powered Nutrunners, AcraDyne Li-Ion 4.1.2 Battery Pack, Capacity, and Signal Display*...
  • Page 3: Incoming Inspection And Packaging

    (model ABG1400). With the second battery pack The product is shipped with the following: included, the number of boltings can be doubled without One (1) AcraDyne ABG Battery-Powered Nutrunner, two (2) interruption. Smart electronics prevent depth discharge of the high-performance Li-ion rechargeable battery packs, and one cells.
  • Page 4: Technical Data

    The AcraDyne ABG Nutrunner has been designed for continuous tightening and loosening of heavy duty nuts and bolts. The power supply must be only through AcraDyne Li- Ion rechargeable battery packs. Other types of rechargeable batteries may cause fires or physical injury. The AcraDyne...
  • Page 5: Operating The Charger Station

    Operation and Service Manual Operating the Charger Station Operating the AcraDyne ABG Nutrunner The charger station must only be used if the The ABG Nutrunner must not be damp or wet, and mains electrical supply matches the voltage and may not be used in a damp or humid environment.
  • Page 6: Battery Pack, Capacity, And Signal Display

    ABG Battery-Powered Nutrunners 4.1.2 Battery Pack, Capacity, and Signal Display* Preparing for Work with the Power Tool Before preparing the power tool for work remove the Li-Ion battery pack from the tool. Depending on the specific job, various adapters for tightening and loosening of bolted connections are needed.
  • Page 7: Electric Operation

    Torque chart (sample) Direction left (counter-clockwise, loosening). Push the slide switch Your AcraDyne HT Nutrunner has been adjusted according to this torque completely to the right. chart. Repeatable accuracy of shut-off is ±3%. In the torque table, each position number is assigned a respective torque.
  • Page 8: Manual Adjustment Of Shut-Off Torque

    ABG Battery-Powered Nutrunners When the set torque value has been reached, the tool will Using the measures shown in the image, you can shift the switch off precisely and an audible signal (beep) will sound. characteristic line in the upper and lower part. Actuate the slide switch only when the motor is stopped.
  • Page 9: Tightening And Loosening

    Operation and Service Manual 6.1.1 Tightening and Loosening Work steps Always place the socket/connector completely and safely on the bolt/nut. The support of the reaction bar to absorb the reaction torque must always be safe and stable. Please consult your AIMCO partner for customized reaction bar solutions.
  • Page 10: Function And Operation Test

    AIMCO partner. Decommissioning Servicing / Storage / Maintenance If the AcraDyne tools and devices are not used Replacing Accessories over an extended period of time, they should be cleaned and stored in a dry and closable space See section 4.2 Preparing for Work with the Power Tool.
  • Page 11: Technical Notes

    In order to prevent faulty boltings or damages to If the battery pack is very warm to the touch, it is the power tool, the AcraDyne AGB Nutrunner is recommended to cool it in the charger station. The fitted with a multi-functional monitoring system.
  • Page 12 CORPORATE HEADQUARTERS AIMCO CHINA AIMCO SOUTH KOREA 10000 SE Pine Street Room 607, No. 3998 Hongxin Rd B-1213, 167, Songpa-Daero Portland, Oregon 97216 Minhang District, Shanghai Songpa-Gu, Seoul 05800 Phone: (503) 254–6600 China South Korea Toll Free: 1-800-852-1368 Phone: 0086-21-34319246 Phone: 0082-2-2054-8930 Fax: 0086-21-34319245 Cell: 0082 10 9804 8905...