1.

Technical Data

AcraDyne Li-Ion rechargeable battery pack:
Voltage 18 V, 5.2 Ah
Charging time approx. 100 min.
AcraDyne charger station:
220-240 V / 50-60 Hz / 65 W
Output 12-42 V / 3.0 A max (optional 110 V / 50 Hz)
2.

Safety Instructions

2.1

Intended Use

The AcraDyne ABG Nutrunner has been designed for
continuous tightening and loosening of heavy duty nuts and
bolts. The power supply must be only through AcraDyne Li-
Ion rechargeable battery packs. Other types of rechargeable
batteries may cause fires or physical injury. The AcraDyne
charger station has been dimensioned exclusively for charging
AcraDyne Li-Ion rechargeable battery packs.
Any other use is considered improper. Any damages resulting
from improper use are the responsibility of the user.
2.2

Operator Responsibilities

The user is obliged to read the operating and maintenance
instructions before using or servicing the device. The device
must only be used by persons aware of the purpose, the
consequences of their action, and the precise usage of the
device. Users must not be under the influence of intoxicating
substances, e.g. drugs, alcohol, medication.
For further information on the safety measures and applications,
please contact your AcraDyne partner.
Incorrect or improper use, or operation by
unqualified personnel can result in severe
physical injury and material damage.
The user is responsible for any third parties
accessing the work zone.
The AcraDyne charger station must not be used
in areas with an explosion hazard rating. Always
observe the locally applicable and relevant safety
instructions.
Independent modifications or changes on the
product are not permissible.
ABG Battery-Powered Nutrunners
2.3

Hazard notices

In case of mechanical or electrical damages to the
Li-Ion battery pack or charger station, use of the specific
device must be interrupted immediately. The damaged
unit must be inspected for mechanical or electrical
damages and safety. Defects must be repaired by
qualified personnel and before renewed use.
Before repairing mechanical or electrical components or devices
always disconnect the rechargeable power pack and the mains
power supply from the power supply to the power tool.
Do not use deformed or defective battery packs. Do
not attempt to open battery packs. Do not touch or
short battery pack contacts. Keep away from small
metal objects that could cause an electrical short
between contacts. A short circuit can cause fire
and physical injury through burns.
A slightly acidic and flammable liquid may seep out of
defective Li-Ion rechargeable batteries. If the battery
liquid comes into contact with skin immediately
rinse with plenty of water. If battery liquid comes into
contact with an eye, immediately rinse and wash with
plenty of water and consult a physician.
Do not attempt to charge non-rechargeable
batteries. Doing so could cause an explosion.
Do not recharge fully charged batteries!
Keep children away from the charger station and
the work area.
In case of smoke or fire from the charger station
immediately pull out the electric mains supply plug.
Do not insert objects in the ventilation slots of the
charger station. This could result in electric shock or
short circuit.
4
Protect rechargeable battery packs
(1) against dampness and wetness
and do not subject to open fire.
Do not use the charger station outdoors.
Protect
the
charger
station
dampness and wet.
against