AB-CTA & AB-MTA CORDLESS TOOL
OPERATING INSTRUCTIONS
ABP Model
ABS Model
ABN Model
ABT Model
ABP High Torque Model
10000 SE Pine St., Portland, Oregon 97216
Phone: (503) 254-6600, 1-800-852-1368
www.aimco-global.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AB-CTA and is the answer not in the manual?

Questions and answers

Summary of Contents for AcraDyne AB-CTA

  • Page 1 AB-CTA & AB-MTA CORDLESS TOOL OPERATING INSTRUCTIONS ABP Model ABS Model ABN Model ABT Model ABP High Torque Model 10000 SE Pine St., Portland, Oregon 97216 Phone: (503) 254-6600, 1-800-852-1368 www.aimco-global.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. IMPORTANT INFORMATION 2. GENERAL INFORMATION 2.1.0. Importance of the operating instructions ....7 2.2.0. Proper intended use ....... 7 2.3.0.
  • Page 3 Disposal Power tools, batteries, accessories and packaging must be disposed of at an environmentally-compatible recycling facility. Power tools and batteries do not go into the household trash. Transport Li-Ion batteries are subject to specifications in the laws pertaining to hazardous goods. The batteries can be transported on roads by the user without further constraints.
  • Page 4 Pistol Tool Features Straight and Angle Tool Features Angle Tool Straight Tool OLED Display Optional scanner Multi-color LED control light Premium Li-Ion battery Brushless high-powered 1/4” hex socket adapter (Pistol motor Tool) 13a 1/4” hex socket adapter (Straight Color index CW / CCW switch Tool) 13b 3/8”...
  • Page 5 High Torque Pistol Tool Features OLED Display Optional scanner Multi-color LED control light Premium Li-Ion battery Brushless high-powered 1” square drive motor Clutch Access (MTA models) Color index High torque gearbox CW / CCW switch Spline Large trigger Reaction bar Ergonomical handle Retaining ring USB interface (in battery...
  • Page 6 Tool configuration determines which functions can be used. Furthermore each basic function has many subfunctions. FEATURE MODEL MODEL Clutch Shut-Off Tool that Measures Torque and Reports Angle Transducer Shut-Off Tool that Controls Torque and Angle Clutch Shut-Off Tool that Monitors Torque as Determined by Current and Reports Angle Five Programmable Configurations with only one tool:...
  • Page 7: Important Information

    1. IMPORTANT INFORMATION Before you put the tool down, wait until it has come to a complete stop; otherwise, the tool can jam and you may lose control of the tool. When tightening and loosening fasteners, high reaction torques can occur. Therefore, always keep a tight grip on the tool.
  • Page 8: Improper Use

    2.4.0. GUARANTEE AND LIABILITY NEW TOOL AND ACCESSORY WARRANTY Any new tool or accessory branded with the AIMCO, Uryu, AcraDyne or Eagle Industries name, and purchased from AIMCO, or through one of its authorized distributors or agents, is warranted to the original buyer against defects in materials and workmanship for a period of one (1) year* from date of delivery.
  • Page 9 The warranty provision with respect to each such product may be amended by AIMCO from time to time in its sole discretion. The liability of AIMCO hereunder shall be limited to replacing or repairing, at its option, any products which are returned freight prepaid to AIMCO and which AIMCO determines to be defective as described above or, at AIMCO’s option, refunding the purchase price of such products.
  • Page 10: Basic Safety Instructions

    3. BASIC SAFETY INSTRUCTIONS 3.1.0. NOTICES IN THE OPERATING INSTRUCTIONS • The basic requirement for safe and proper use and fault-free operation is knowledge of the basic safety instructions and safety regulations. • In addition, the rules and regulations for the place of use must be followed.
  • Page 11: Danger From Electrical Energy

    3.4.0. DANGER FROM ELECTRICAL ENERGY Only allow a qualified electrician to perform work on this tool. The electrical equipment of the tool must be regularly inspected. Loose connections and charred cables must be immediately repaired. If work must be performed with the tool, remove the battery prior to opening the device.
  • Page 12: Personal Safety

    3.4.4. Personal safety a) Be careful, pay attention to what you are doing, and use power tools responsibly. Do not use power tools when you are tired or under the influence of drugs, alcohol, or medication. One moment of carelessness when using the tool can lead to severe injuries. b) Always wear personal safety equipment and protective eyewear.
  • Page 13: Service

    g) Use the tool, accessories, etc. in accordance with these instructions. Take the working conditions and task to be executed into account. The use of power tools for other purposes than the intended use can lead to hazardous situations. h) Use the right tool. Do not use low-output tools for heavy loads. Do not use the tool for purposes and work for which it is not intended.
  • Page 14 c) If the battery is unused for an extended period of time, it must not remain on the charger or on the tool. If a work break of more than 3 hours is expected, the battery must be removed from the tool. Otherwise, the battery may be permanently damaged.
  • Page 15: Cleaning And Disposing Of The Tool

    Lithium-ion batteries have nearly no self-discharge and do not have a memory effect. If properly used, they will reliably supply your tool with power for several years (approx. 700 - 1000 charge cycles). In general, avoid deep discharging or overcharging the lithium-ion battery under any circumstances.
  • Page 16: Start-Up

    4. START-UP Do not let the tool fall or allow other objects to fall on the device. Protect it from impact damage. Make sure that the device does not come into contact with sprayed water or oil. 4.1.0. INSTALLING OR REMOVING THE BATTERY •...
  • Page 17: Rotating Direction Switch

    4.1.2. Rotating direction switch Before you remove the battery or install it on the tool, please check that the rotating direction switch is in the neutral position. Always check the rotating direction switch prior to operation. Rotating Rotating direction direction switch switch To change the rotating direction, the tool is equipped with a rotating...
  • Page 18: Reaction Bar Attachment/Geometry/Safety

    4.1.3. Reaction Bar Attachment/Geometry/Safety On ABP-CTAxxx models equipped with a GearBox for delivering higher torque forces, a reaction bar used to counteract torque reaction to the operator MUST be used A simple clutch that allows Reaction Bar the Gearbox to rotate 360 degrees in either direction related to the motor/handle assembly is built into the...
  • Page 19 • Reattach the battery without pressing the trigger to avoid unintentional start THE TOOL HANDLE MUST NOT BE LOCATED AGAINST AN OBJECT OR RESTRICTION DURING OPERATION OF THE TOOL TO AVOID CREATION OF A PINCH POINT. AN OEM SOURCED OR APPROVED REACTION BAR OR PROPER REACTION ABSORPTION DEVICE MUST BE IN USE AND IN GOOD CONDITION ANY TIME THE TOOL IS OPERATED.
  • Page 20: Reaction Bar Safety

    SERIOUS PERSONAL INJURY, LOSS OF LIMB, OR DEATH. The guidelines offered below are only guidelines. Should there be any doubt as to the integrity of a proposed reaction strategy, it is strongly advised to consult with an AcraDyne authorized representative prior ®...
  • Page 21 ABP-CTAxxx Series Nutrunners. Mechanic-grade chrome sockets are not to be used as they do not have sufficient structural strength required to deliver the higher torque loads that an AcraDyne® ABP- CTAxxx Series Nutrunner is capable of delivering. In addition, the use of...
  • Page 22: Led / Barcode Scanner

    After pressing the trigger, the LED and the barcode scanner will switch on. The afterrun illumination of the LED after the trigger has been pressed can be defined in the AcraDyne Tool Manager under Settings - General. The released barcode scanner goes off after a barcode is successfully scanned and/or the trigger has been released.
  • Page 23: Setting The Tightening Torque

    If the requested value isn´t reached, adjust the clutch again. For the CTA Series, the tool will be programmed with AcraDyne Tool Manager software. Make sure that the tool is configured and parameterized correctly. See the AcraDyne Tool Manager user manual for operating instructions.
  • Page 24: Back-Up Strategy

    If the connection to the process controls cannot be restored, the fastening process results must be manually secured (read out of the tool using the AcraDyne Tool Manager software and saved). Then, after removing the battery, the back-up strategy can be used to continue working.
  • Page 25 The fastening results are not transmitted to the process controls for central storage. You can, however, read the fastening process results with AcraDyne Tool Manager software and save them as a file. Go forward with the menu button until the "Scanner M" logo appears.
  • Page 26: Operation

    In the Info menu, the most current battery voltage, network coverage RSSL, and the version of the firmware can be displayed. In the Scanner menu, the scanner can be selected to read in network settings using a barcode. Scanning for program selection is not possible in this mode.
  • Page 27: Display

    Status description Torque Angle in degrees Display elements can be modified in AcraDyne Tool Manager so the worker is shown, for instance, precise values for the fastener joints, rotational angle, only an OK or NOK, or the counting process. You can set in which unit the values are output (Nm, lbf.in, lbf.ft).
  • Page 28: Status Displays

    5.1.0. STATUS DISPLAYS Battery Status 50% - 100% 30% - 50% 10% - 30% 5% - 10% Less than 5% Network Status Tool tries to Tool has lost Tool has found Previously lost dial into the the connection the network connections network.
  • Page 29 Symbol can also be a car. Tool is locked and is currently being configured using the AcraDyne Tool Manager via WiFi. Battery must not be removed. The fastening process for one or more fasteners was not processed within the specified time.
  • Page 30 Status Display NOK must be separately confirmed by the worker pressing a button on the display. Tool has received a release for program 3. This will unfasten the fastener with 3.00 Nm. Tool has received a release for program 3. This will process the fastener with 3.00 Nm.
  • Page 31 The NOK-screwing in front needs to be acknowledged. This can be programmed in the settings with the AcraDyne Tool Manager. Battery was installed, tool starts, but cannot connect to the network. Press the trigger to start a new connection.
  • Page 32 AIMCO. Many displays can deviate slightly depending on the software settings. For more information, look at your settings and the operating instructions for AcraDyne Tool Manager. If an error occurs several times, please contact the AIMCO support team. The display elements (status notifications) were created partially with and partially without a Wi-fi connection to a superordinate control system.
  • Page 33 Error Displays Maximum allowable torque exceeded, contact the manufacturer. Maximum allowable current exceeded, contact the manufacturer. Temperature of the controls exceeded, contact the manufacturer. Temperature of the motor exceeded, contact the manufacturer Maximum logic voltage exceeded, tool must be repaired. SD card not found in the tool or is defective.
  • Page 34: Accessories

    6. ACCESSORIES All tools are delivered with software Improper use of potential supplemental devices or accessories from other manufacturers may pose a risk (of injury) to persons. Only use supplemental devices or accessories for the intended purpose. We will gladly assist you if you have questions.
  • Page 35: Technical Data

    ABT-CTA15W ABT-CTA20W 5 – 20 3.7 – 14.8 3/8” – 5/8” hex. W = WiFi option B = Barcode option Q = Quick Change AcraDyne Cordless AB-CTA Ultra Torque Series Tools Gearbox Max Torque Max Speed Length Diameter Model FT-LB Weight w/out battery: 3.7 kg / 8.04 lb...
  • Page 36 13.9 2.81 — — TUBENUT ABT-CTA15W 22.2 7.82 4.17 12.7 ABT-CTA20W 22.9 8.39 4.74 0.56 AcraDyne Cordless AB-CTA Ultra Torque Series Tools Tool Dimensions Model ABP-CTA250 (W) 14.1 0.89 2.65 ABP-CTA450 (W) 14.1 0.89 2.65 ABP-CTA650 (W) 14.1 0.89 2.65 ABP-CTA950 (W) (DL) 14.1...
  • Page 37: Mta Model Specifications

    7.2.0. MTA MODEL SPECIFICATIONS Torque Range Max Speed Drive Weight w/o Battery Model FT-LB Type PISTOL ABP-MTA06 (Q) (WQ) (BQ) (WBQ) 1.0 – 6 0.8 – 4.4 1,100 1/4” QC 1.25 2.75 ABP-MTA08 (Q) (WQ) (BQ) (WBQ) 1.5 – 8 1.1 –...
  • Page 38 MTA Model Dimensions Straight Pistol Angle Tool Dimensions Model PISTOL ABP-MTA06 (Q) (WQ) (BQ) (WBQ) 1.02 8.56 ABP-MTA08 (Q) (WQ) (BQ) (WBQ) 1.02 8.56 ABP-MTA12 (Q) (WQ) (BQ) (WBQ) 1.02 8.56 ABP-MTA17 (Q) (WQ) (BQ) (WBQ) 1.02 8.56 STRAIGHT ABS-MTA06 (Q) (WQ) (BQ) (WBQ) 17.2 3.19 0.79...
  • Page 39 - 39 -...
  • Page 40 CORPORATE HEADQUARTERS AIMCO CORPORATION DE MEXICO SA DE CV 10000 SE Pine Street Ave. Cristobal Colon 14529 Portland, Oregon 97216 Chihuahua, Chihuahua. 31125 Phone: (503) 254–6600 Mexico Toll Free: 1-800-852-1368 Phone: (01-614) 380-1010 WWW.AIMCO-GLOBAL.COM Fax: (01-614) 380-1019 LIT-MAN231 Rev. 10/21 Printed in USA ©2021 AIMCO...

Table of Contents