1.0 Unpacking:
Remove the EkoMini
EkoMini repeater kit was purchased, donor and server antennas should have been
received in separate shipping containers.

2.0 Additional Parts Needed for Installation:

Since every installation is different, other parts may need to be provided by the
installer:
• Donor antenna, unless an EkoMini
• Server antenna(s), unless an EkoMini
• 50 ohm Coaxial power splitter, if more than one server antenna is
needed.
• 50 ohm ½" flexible coaxial cable, plenum rated if required by building
code.
• Type N male connectors (or DIN 7-16, depending on the antenna
connector option)
• Mounting hardware for the donor antenna
• Weatherproofing compound
• Other miscellaneous installation items

3.0 Pre-setting the Configuration Switches:

TM
The EkoMini
is shown in Figure 1. It has a set of eight configuration "DIP" switches
located under a small removable panel. See Figure 2. For many installations, these
switches are set properly at the factory. However, they can be verified or changed
using this procedure:
• Remove the small switch panel with a Phillips head screwdriver.
• The switches are numbered 1 through 8, as shown in Figure 2
below. They can be turned "on" or "off" using a small screwdriver or
a bent paper clip. Note that each switch is "off" when it is pushed
"up" toward the repeater mounting flange.
• Position each of the eight switches as described below.
TM
repeater and the external power supply from the box. If an
TM
kit was purchased.
TM
kit was purchased.