EMS EkoMini Installation Manual page 12

Hide thumbs Also See for EkoMini:
Table of Contents

Advertisement

button. Normal operation should occur. If it does not, perform a "hard
reset" described in step 2.
• Step 2 – "Hard Reset": Again using a bent paperclip, press and hold
the reset button. While the button is held down, remove the DC power
cable from the repeater, and then plug the cable back in. Continue to
hold the reset button for approximately 45 seconds, and then release
it.
This procedure completely resets the repeater's microprocessor
and other software settings. Normal operation should occur. Note: If
the remote alarming option is installed, this "hard reset" will reset all
user names and passwords back to the factory default settings
described in the Operator's Manual.
Other troubleshooting procedures are described in the table below.
Problem
No
Power
power LED is off)
Alarm Light is On
Low Downlink Signal,
possibly with alarm
issued
Uplink
–10
signal level is on
Probable Cause
(Green
Power
problem
No Downlink Signal
Donor
mis-aligned, DL cable
is faulty, BTS is not
line of sight, BTS is
excessively far from
repeater site, etc.
dBm
Normal condition if no
mobile phones are in
use near the repeater
Corrective Action
Supply
Reconnect
supply to repeater.
Verify
source; plug in power
supply if necessary.
Check
signal level with a
spectrum analyzer.
Check band switches
3 and 4 on PCS
models.
antenna
is
Measure
signal level with a
spectrum analyzer.
Improve DL signal by
raising
antenna, re-orienting
the donor antenna,
re-orienting
shorten cable runs,
etc.
Activate
phone and move it
close to the server
antenna.
power
AC
power
downlink
downlink
the
donor
unit
to
a
mobile
UL signal

Advertisement

Table of Contents
loading