    SUMMARY 1. PRESENTATION ........................11 2. DESCRIPTION ........................11 3. OPERATING PROCEDURE ....................11 3.1. Switching ON .......................11 3.2. DC Zero adjustment ....................11 3.3. Measurement .......................12 3.4. Overload indication ......................12 3.5. Auto OFF ........................12 4. SPECIFICATIONS ........................12 4.1. Reference conditions ....................12 4.2. Operating conditions ....................13 4.3.
  • Page 4: Presentation

    1. PRESENTATION The PAC 11 current clamp measures DC or AC currents, without opening the circuit they are flowing in. The current clamp is used as an accessory for multimeters, recorders, etc. This clamp measures DC currents up to 600 A and AC currents up to 400 A rms (600 A peak). It outputs the form and amplitude of the current measured as a voltage image of the primary current.
  • Page 5: Measurement

    60 A on the 40 A range (10 mV/A) or 600 A on the 400 A range (1 mV/A). 3.5. AUTO OFF The PAC 11 has an Auto Off feature which switches off 10 minutes after the clamp has been switched on, without the controls being used.
  • Page 6: Operating Conditions

    4.2. OPERATING CONDITIONS The instrument must be used in the following conditions to satisfy the safety of the user and the metrological performance : - Use indoors ≤ - Working altitude : 2000 m ≤ - Transportation altitude : 12 000 m - Environmental conditions : see graph below 4.3.
  • Page 7 „ Phase error (45 ... 65 Hz) Primary current 10 ... 20 A 20 ... 40 A Phase shift ≤ ≤ 3° 2.2° ≤ - Rise time from 10 to 90 % Vs : 100 µs ≤ - Fall time from 90 to 10 % Vs : 100 µs ≤...
  • Page 8: Mechanical Specifications

    4.4. MECHANICAL SPECIFICATIONS - Watertightness : IP 30 in accordance with IEC 529 - Clamping diameter : 1 cable ∅ 30 mm (or 2 cables ∅ 24 mm) a busbar of cross section 50 x 10 mm - Outside dimensions of clamp : 224 x 97 x 44 mm - Fitted lead : 1.5 m - Weight :...