PINCE POUR OSCILLOSCOPE
CLAMP FOR OSCILLOSCOPE
ZANGENSTROMWANDLER FÜR OSZILLOSKOP
PINZA PER OSCILLOSCOPIO
PINZA PARA OSCILOSCOPIOS
F R A N C A I S
Mode d'Emploi
E N G L I S H
User's Manual
D E U T S C H
Bedienungsanleitung
I T A L I A N O
Libretto d'Istruzioni
E S P A N O L
Manual de Instrucciones
PAC 12
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PAC 12 and is the answer not in the manual?

Questions and answers

Summary of Contents for Chauvin Arnoux PAC 12

  • Page 1 PAC 12 PINCE POUR OSCILLOSCOPE CLAMP FOR OSCILLOSCOPE ZANGENSTROMWANDLER FÜR OSZILLOSKOP PINZA PER OSCILLOSCOPIO PINZA PARA OSCILOSCOPIOS F R A N C A I S Mode d'Emploi E N G L I S H User's Manual D E U T S C H...
  • Page 2 (extract from our General Conditions of Sale, available on request). TO ORDER Ref. Oscilloscope Clamp PAC 12 CVH ............P01.1200.72 Supplied with a 9 V alkaline battery, a set of labels in 5 languages to stick to the instrument, and a User Manual.
  • Page 3: Table Of Contents

    SUMMARY page 1 Presentation ................................2 Description ................................3 Operating procedure ............................3.1 Switching on ............................3.2 DC zero adjustment ........................3.3 Measurement ............................. 3.4 Overload indication ........................3.5 Auto off ..............................4 Specifications ............................... 4.1 Reference conditions ........................4.2 Operating conditions ........................
  • Page 4: Description

    2/ DESCRIPTION See descriptive diagram at the end of the User Manual. Passage of the conductor Jaws Protective non-slip guard Automatic zero DC button Red fault light (over range / incorrect zero adjustment) Green light indicating correct power supply 3-position sliding switch (off / selection of 1 mV/A or 10 mV/A ranges) Hand-held parts Fitted lead 1.5 m BNC plug...
  • Page 5: Overload Indication

    3.4/ OVERLOAD INDICATION Detection of overload of the range of the clamp is indicated by the red light . This indicator flashes for a peak current greater than 60 A on the 40 A range (10 mV/A) or 600 A on the 400 A range (1 mV/A). 3.5/ AUTO OFF The clamp has an Auto Off feature which switches off 10 minutes after the clamp has been switched on, without the controls being used.
  • Page 6: Metrological Specifications

    Reference Storage Stockage Utilisation Réference % RH °C Temperature 4.3/ METROLOGICAL SPECIFICATIONS All the errors are indicated as a % of Vs (value of the output voltage) - Output impedance: 100 Ω - Zero adjustment: ± 10 A by automatic step from 25 to 40 mA approx. 40 A range (10 mV/A) Intrinsic error in the field of reference Primary current...
  • Page 7: 400 A Range (1 Mv/A)

    400 A range (1 mV/A) Intrinsic error in the reference range Primary current 0.5...100 A 100...400 A 400...600 A (on DC only) ≤ 1.5% + 1 mV ≤ 2% ≤ 2.5% Accuracy Graphs of typical relative error: see appendix, page 45. Phase error (45...65 Hz) Primary current 10...300 A...
  • Page 8: Electrical Specifications

    - Drop height: to IEC 68-2-32 - Protection from shocks: 100 g in accordance with IEC 68-2-27 - Vibrations: to IEC 68 - 2 - 6 4.5/ ELECTRICAL SPECIFICATIONS Power supply: 9 V battery (type 6LR61, 6LF22 or NEDA 1604) Battery life: approx 50h with an alkaline battery Operating limits On DC current: 3000 A permanent...
  • Page 9: Maintenance

    It is essential that all measuring instruments are regularly calibrated. For checking and calibration of your instrument, please contact our accredited laboratories (list on request) or the Chauvin Arnoux subsidiary or Agent in your country. 5.4/ MAINTENANCE Repairs under or out of guarantee: please return the product to your distributor.