▶ Remove the four screws that retain the cover plate to the
gas manifold, see fig. 47 (plate in grey color).
Fig. 47
Gas manifold
▶ Remove metal plate and seal.
▶ The 3 restrictor plates should be pre-assembled onto their
tray, but if loose in box, follow installation instructions, as
shown in fig. 48 and 49[1].
▶ Insert the LP conversion plate in the appropriate location
shown in fig. 48 and 49 [2].
CAUTION:
▶ All three flow restrictors and seal must
be assembled according to the fig. 48
and 49, to assure correct appliance
performance.
Fig. 48
199kBTU appliance gas conversion kit
Greentherm T9800 SE 160/199 | SEC 199
Fig. 49
160kBTU appliance gas conversion kit
▶ Tighten the four screws.
▶ Open the gas supply valve.
▶ Turn On the appliance.
▶ Check for gas leak (e.g. use leak detector fluid, like water
and soap, over and around the metal plate) and act
accordingly.
▶ Replace the front cover.
▶ Access the Technical Settings menu (section 6.6).
▶ Access to menu P7 Gas Type.
Display shows appliance gas type.
▶ Use the symbols
▶ Touch the symbol
The display blinks to confirm the change.
L'appareil passera par un processus
d'initialisation.
▶ Update "TYPE OF GAS" in the rating plate of the appliance
using the label provided with the conversion plates.
▶ Confirm CO
and CO values and, if necessary, adjust Gas
2
and Air flow parameters, see chapter 8.11 for more
information.
Operating Instructions | 49
or
to choose gas type LPG.
.
6 720 816 815 (2018/08)