Download Print this page

Specifications - Panasonic SF-C13 Instruction Manual

Control unit exclusive for light curtain
Hide thumbs Also See for SF-C13:

Advertisement

11

SPECIFICATIONS

Model No.
Item
Connectable input device Light curtains manufactured by Panasonic Industrial Devices SUNX
EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1: 2008 (Category 4,PLe)
IEC 61496-1 (Type 4) ISO 13849-1: 2006 (Category 4, PLe)
JIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4)
Applicable standard
ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2)
Ministry of Health, Labour and Welfare model examination certified product
No. TA527 (SF4B-A□-01<V2>)
No. TA528 (SF4B-F□-01<V2>, SF4B-H□-01<V2>)
Supply voltage
24V DC±10% Ripple P-P 10% or less
Built-in electronic fuse, Breaking current: 0.5A or more reset
Fuse rating
by power supply stop
Safety output (Note 1)
30V DC / 4A, 230V AC / 4A
Rated operation
Resistance load (the contact protection for inductive load)
voltage / current
Minute current: 10mA or more (at 24V DC)
Contact protection fuse rating
Contact material / contacts
AgSnO, Self cleaning, positively driven
Contact resistance (Initial value)
Mechanical lifetime
10,000,000 times or more (switching frequency 180 times/min.) (Note 2)
100,000 times or more (switching frequency 20 times/min. at
Electrical lifetime
230V AC / 3A, resistive load) (Note 2)
Auxiliary output
Safety relay contact (NC contact) × 1 (interlocked to safety output)
Rated operation
24V DC / 2A, Minute current: 10mA or more (at 24V DC)
voltage / current
Contact protection fuse rating
PNP open-collector transistor
• Maximum source current: 60mA
Semiconductor auxil-
• Applied voltage: same as supply voltage
iary output
(between the Semiconductor auxiliary output and +V)
(AUX terminal)
• Residual voltage: 2.3V or less (at 60mA source current)
• Leak current: 2mA or less
Output operation
Current consumption
Application category
Pick-up delay
80ms or less / 90ms or less (Auto reset / Manual reset)
Response time (Drop-out delay)
Protection
(This product must be installed into a control box having IP54 construction.)
Pollution degree
-10 to +55°C (No dew condensation or icing allowed)
Ambient temperature
Storage: -25 to +70°C
Ambient humidity
30 to 85% RH, Storage: 30 to 95% RH
No malfunction when tested with 10 to 55Hz frequency, 0.35mm
Vibration resistance
amplitude in X, Y and Z directions for twenty times each
Overvoltage category
B
(Note 3)
Minimum load: 20,000,000, Maximum load: 400,000
10d
Mission time
Connection terminal
Material
Weight
Notes: 1) Timing chart of the safety output is diagram below.
Light received
Light received status
Light blocked
ON
Control output 1 / 2 (OSSD
1 / 2) of light curtain
OFF
ON
Safety input of this device
OFF
2) The lifetime of the switch of relay depends on type of the load, frequency of
switching or environment etc.
3) Mean cycle time that 10% of parts reach dangerous failure.
12
CAUTIONS
● In case this unit is connected to a product other than the connectable
input devices, this unit doesn't meet the control category 4 specified in
ISO 13849-1 (EN ISO 13849-1).
● This product has been developed / produced for industrial use only.
● Make sure that the power is OFF while wiring.
● Take care that wrong wiring will damage the product.
● Verify that the supply voltage variation is within the rating.
● Take care that if a voltage exceeding the rated range is applied, or if an
AC power supply is directly connected, the product may get burnt or
damaged.
● The DC power supply unit must satisfy the conditions given below:
1) Power supply unit authorized in the region where this device is to be
used.
2) Power supply unit SELV (safety extra low voltage) / PELV (protected
extra low voltage) conforming to EMC Directive and Low-voltage Di-
rective (In case CE Marking conformity is required.)
3) Power supply unit conforming to the Low-voltage Directive and with
an output of 100VA or less.
4) The frame ground (F.G.) terminal must be connected to ground
when using a commercially available switching regulator.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
SF-C13
NO contact × 3
4A (slow-blow)
100mΩ or less
2A (slow-blow)
Dark-ON
100mA or less (without light curtain)
AC-15, DC-13 (IEC 60947-5-1)
10ms or less
Enclosure: IP40, Terminal: IP20
2
II
20 years
Spring gauge terminall
Enclosure: ABS
Approx. 200g
Response time of Light curtain
10ms or less
5) Power supply unit with an output holding time of 20ms or more.
6) In case a surge is generated, take countermeasures such as con-
necting a surge absorber to the origin of the surge.
7) Power supply unit corresponding to CLASS 2 (only for requiring
UL
Mark conformation).
C
US
● Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.
● Avoid dust, dirt, and steam.
● Take care that the product does not come in contact with water, oil,
grease, or organic solvents such as thinner, etc.
● The seal as shown in the drawing on the right
is stuck to the engagement point of unit. When
the seal is peeled off or broken, this equipment
will not be certified as a "Safety equipment"
and will not be covered by our guarantee.
● Note that this equipment is applicable only in the control circuit grounded in
accordance with IEC 60204-1 and JIS B 9960-1, or in the control circuit in
which the insulation monitor unit (ground fault detection unit) is arranged.
● This product is suitable for indoor use only.
13
DIMENSIONS (Unit: mm)
4
35
67.3
130
6.5
10
13.5
Suitable for 35mm width DIN rail
14
INTENDED PRODUCTS FOR CE MARKING
● The model listed under "
CE Marking.
As for all other models, please contact our office.
CE MARKING DECLARATION OF CONFORMITY
15
Itemized Essentials of EU Declaration of Conformity
Manufacturer's Name: Panasonic Industrial Devices SUNX Co., Ltd.
Manufacturer's Address:
2431-1, Ushiyama-cho, Kasugai, Aichi 486-0901, Japan
EU Representative's Name:
Panasonic Marketing Europe GmbH Panasonic Testing Center
EU Representative's Address:
Winsbergring 15, 22525 Hamburg, Germany
Product: Exclusive Control Unit for Light Curtain
Model Name: SF-C10 Series
Trade Name: Panasonic
Application of Council Directive:
- 2006/42/EC Machinery Directive
- 2004/108/EC EMC Directive
- 2011/65/EU RoHS Directive
Harmonized standards:
- EN 61496-1: 2013
- EN ISO 13849-1: 2008
- EN 55011: 2009+A1: 2010
- EN 50581: 2012
Type Examination: Certified by TÜV SÜD Product Service GmbH
Ridlerstrasse 65 80339 München Germany
6.75
5
34.5 3 × 5 = 15
91.6
80
13
80.8
22.5
SPECIFICATIONS" comes with
6
5

Advertisement

loading