Kongsberg cNODE MiniS 1.11-50V Ti Instruction Manual
Kongsberg cNODE MiniS 1.11-50V Ti Instruction Manual

Kongsberg cNODE MiniS 1.11-50V Ti Instruction Manual

Hide thumbs Also See for cNODE MiniS 1.11-50V Ti:
Table of Contents

Advertisement

Quick Links

cNODE MiniS 1.11-50V Ti
Transponder
Instruction Manual
436538/A
July 2018 © Kongsberg Maritime AS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the cNODE MiniS 1.11-50V Ti and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kongsberg cNODE MiniS 1.11-50V Ti

  • Page 1 MiniS 1.11-50V Ti Transponder Instruction Manual 436538/A July 2018 © Kongsberg Maritime AS...
  • Page 2 Kongsberg Maritime disclaims any responsibility for damage or injury caused by improper installation, use or maintenance of the equipment. Disclaimer Kongsberg Maritime AS endeavours to ensure that all information in this document is correct and fairly stated, but does not accept liability for any errors or omissions. Support information If you require maintenance or repair, contact Kongsberg Maritime’s support organisation.
  • Page 3: Table Of Contents

    GENERAL ACOUSTIC CONSIDERATIONS ........ 11 GETTING STARTED ..............13 Charging the battery (on-deck) ..................14 Turning on the cNODE MiniS 1.11-50V Ti ..............15 Connecting the transponder to external power and responder signals......15 Changing between responder and transponder mode ............16 Pre-deployment checks ....................16 Deployment........................17...
  • Page 4 MiniS 1.11-50V Ti Interface cable Spare part....................28 TTC 10 (Transponder Test and Configuration unit) Spare part ........29 Test and configuration cable (TTC to MiniS) spare part ..........29 Test and configuration cable (PC to MiniS) Spare part ...........29 DRAWING FILE..............30 MiniS 1.11-50V Ti Outline dimensions................31...
  • Page 5: About This Manual

    MiniS 1.11-50V Ti. Target audience This manual is intended for all users of the cNODE MiniS 1.11-50V Ti. Online information All end-user manuals provided for operation and installation of your cNODE MiniS 1.11-50V Ti can be downloaded from our website.
  • Page 6: Kongsberg Cnode Minis 1.11-50V Ti

    MiniS 1.11-50V Ti Instruction Manual Kongsberg cNODE MiniS 1.11-50V Ti Topics System description, page 7 Naming description, page 7 System units, page 8 General supply conditions, page 9 Support information, page 10 436538/A...
  • Page 7: System Description

    HiPAP and cPAP transceivers. cNODE MiniS 1.11-50V Ti is designed to be a very versatile system with many interchangeable parts. The cNODE MiniS 1.11-50V Ti transponders are used with HiPAP and cPAP systems in underwater positioning and are ideal for positioning ROVs. They have responder and transponder functionality, SSBL and LBL positioning, and telemetry capabilities.
  • Page 8: System Units

    The transponder test and configuration unit is designed for on deck testing and configuration of the transponders. The TTC can test all Kongsberg Transponder low frequency channels, Cymbal and HPR 400. It can also test telemetry Transponders with internal and external sensors.
  • Page 9: General Supply Conditions

    All equipment must be inspected for physical damage, i.e. broken controls and indicators, dents, scratches etc. during unpacking. If any damage to the equipment is discovered, the recipient must notify both the transportation company and Kongsberg Maritime so that Kongsberg Maritime can arrange for replacement or repair of the damaged equipment.
  • Page 10: Support Information

    Support information Should you need technical support for your cNODE MiniS 1.11-50V Ti you must contact a Kongsberg Maritime office. A list of all our offices is provided on our website. You can also contact our main support office in Norway.
  • Page 11: General Acoustic Considerations

    General acoustic considerations General acoustic considerations Take this information into consideration when deploying the transponders. Acoustic range The depth rating should not be confused with acoustic range. The acoustic range is dependent on many factors, and some of the factors are outside control of the user. Vessel system The directivity and coverage area for the vessel system is different, depending on which system you are using.
  • Page 12 MiniS 1.11-50V Ti Instruction Manual Sound velocity and ray bending Changes in sound velocity through the water column caused by changes in the water temperature and/or salinity can bend the acoustic signal and make it impossible to reach the vessel.
  • Page 13: Getting Started

    Getting started Topics Charging the battery (on-deck), page 14 Turning on the cNODE MiniS 1.11-50V Ti, page 15 Connecting the transponder to external power and responder signals, page 15 Changing between responder and transponder mode, page 16 Pre-deployment checks, page 16...
  • Page 14: Charging The Battery (On-Deck)

    Charging the battery is connected with some risk, please read the information and follow the charge procedure carefully Prerequisites Caution Equalise the temperature of the cNODE MiniS 1.11-50V Ti to between 10 °C and 40 °C before charging it. For on-deck charging, use the cNODE battery charger only. Never charge the battery unattended.
  • Page 15: Turning On The Cnode Minis 1.11-50V Ti

    The transponder can also be used as a responder unit. Prerequisites The transponder must be charged before use. Procedure Use the cable with part number 402462 from Kongsberg. Connect wire 6 and 8 in the pigtail (the ON/OFF function). 436538/A...
  • Page 16: Changing Between Responder And Transponder Mode

    The transponder can also be used as a responder unit. Prerequisites The transponder must be charged before use. Procedure By default when the cNODE MiniS 1.11-50V Ti is turned on it is in transponder mode. When responder trigger signals are received, the mode is automatically changed to responder.
  • Page 17: Deployment

    Getting started If the unit has been altered from the factory pre-sets, check that the unit is configured according to your requirements. Make sure the battery is fully charged. Push the pressure relief valve in to confirm that it is flush with the end cap. Switch the transponder ON by inserting the on/off plug.
  • Page 18 MiniS 1.11-50V Ti Instruction Manual As an extra precaution, it is recommended that the unit is left to soak in fresh water to allow salt to dissolve and diffuse from hard-to-reach areas, such as crevices between mating parts. Leave the unit to soak for 24 hours, or as long as practical conditions allow.
  • Page 19: Cable Layout And Interconnections

    Cable layout and interconnections Cable layout and interconnections Topics Interconnections, page 20 Interconnections for on-deck charging, page 20 Interconnections without external power supply, page 21 Interconnections with external power supply, page 21 436538/A...
  • Page 20: Interconnections

    MiniS 1.11-50V Ti Instruction Manual Interconnections Interconnections for on-deck charging For on-deck charging, use the cNODE battery charger only. 436538/A...
  • Page 21: Interconnections Without External Power Supply

    Cable layout and interconnections Interconnections without external power supply Interconnections with external power supply 436538/A...
  • Page 22: Operating Procedures

    MiniS 1.11-50V Ti Instruction Manual Operating procedures The transponder is operated from the HiPAP operator station APOS. • Refer to APOS online help for descriptions. 436538/A...
  • Page 23: Maintenance

    Maintenance Maintenance Topics Charging the battery (on-deck), page 24 Lubricating SubConn ® connectors, page 25 Battery charger status and troubleshooting, page 25 436538/A...
  • Page 24: Charging The Battery (On-Deck)

    Charging the battery is connected with some risk, please read the information and follow the charge procedure carefully Prerequisites Caution Equalise the temperature of the cNODE MiniS 1.11-50V Ti to between 10 °C and 40 °C before charging it. For on-deck charging, use the cNODE battery charger only. Never charge the battery unattended.
  • Page 25: Lubricating Subconn Connectors

    • Failure in charger/transponder to mains (110 or 220 Vac). connection If the LED indicator is still • Charger might be faulty flashing red: Charger might be faulty Contact your local Kongsberg Maritime office. 436538/A...
  • Page 26 MiniS 1.11-50V Ti Instruction Manual LED indicator What it means How to fix this Red steady • The battery temperature • Let the unit warm up or might be outside the charging cool down to an ambient specification temperature of 10 °C to 40 °C before charging.
  • Page 27: Spare Parts

    Spare parts Spare parts Topics MiniS 1.11-50V Ti Spare part, page 28 Battery charger Spare part, page 28 Adapter cable Spare part, page 28 ON/OFF plug Spare part, page 28 Interface cable Spare part, page 28 TTC 10 (Transponder Test and Configuration unit) Spare part, page 29 Test and configuration cable (TTC to MiniS) spare part, page 29 Test and configuration cable (PC to MiniS) Spare part, page 29 436538/A...
  • Page 28: Minis 1.11-50V Ti Spare Part

    MiniS 1.11-50V Ti Instruction Manual MiniS 1.11-50V Ti Spare part • MiniS 1.11-50V Ti Part name: • 436500 Part number: Battery charger Spare part • cNODE MiniS 1.11-50V Ti Battery Part name: charger 404199 Part number: Adapter cable Spare part •...
  • Page 29: Ttc 10 (Transponder Test And Configuration Unit) Spare Part

    Spare parts TTC 10 (Transponder Test and Configuration unit) Spare part • TTC 10 (Transponder Test and Configuration unit) Part name: • 364845 Part number: Test and configuration cable (TTC to MiniS) spare part • Test and configuration cable, TTC to MiniS Part name: •...
  • Page 30: Drawing File

    MiniS 1.11-50V Ti Instruction Manual Drawing file This chapter lists all the drawings needed for installation and maintenance. Topics MiniS 1.11-50V Ti Outline dimensions, page 31 External connector, page 32 436538/A...
  • Page 31: Minis 1.11-50V Ti Outline Dimensions

    Drawing file MiniS 1.11-50V Ti Outline dimensions Drawing 436502 436538/A...
  • Page 32: External Connector

    MiniS 1.11-50V Ti Instruction Manual External connector The external connector is for configuration, responder, on/off function and charging. Face view (male): Pin 1, 2 and 3 is for configuration. Pin 4 and 5 is for responder function. Pin 6 is for on/off function.
  • Page 33: Technical Specifications

    Technical specifications Technical specifications Topics Performance specifications, page 34 Weight and outline dimensions, page 35 Power requirements, page 35 Environmental requirements, page 36 436538/A...
  • Page 34: Performance Specifications

    MiniS 1.11-50V Ti Instruction Manual Performance specifications These performance specifications summarize the main functional and operational characteristics of the cNODE MiniS 1.11-50V Ti Transponder. MiniS 1.11-50V Ti • : 11000 m Depth range • : 11000 m Operating depth range •...
  • Page 35: Weight And Outline Dimensions

    Technical specifications Weight and outline dimensions These weights and outline dimension characteristics summarize the physical properties of the cNODE MiniS 1.11-50V Ti. MiniS 1.11-50V Ti • Outline dimensions – : 418 mm Height – : 194 mm Diameter • : 20 kg Weight (in air) •...
  • Page 36: Environmental Requirements

    MiniS 1.11-50V Ti Instruction Manual Environmental requirements These environmental specifications summarize the temperature and humidity requirements for the cNODE MiniS 1.11-50V Ti system. MiniS 1.11-50V Ti • : -5 to 55 °C Operational temperature • : -30 to 70 °C...
  • Page 37: Battery Safety

    Battery safety Battery safety Topics SECTION 1: Identification, page 38 SECTION 2: Hazards identification, page 38 SECTION 3: Composition, page 39 SECTION 4: First aid measures, page 40 SECTION 16: Other information, page 40 SECTION 6: Accidental release measures, page 40 SECTION 7: Handling and storage, page 41 SECTION 9: Physical and chemical properties, page 41 SECTION 10: Stability and reactivity, page 42...
  • Page 38: Section 1: Identification

    MiniS 1.11-50V Ti Instruction Manual SECTION 1: Identification The specification describes the technical parameters for the battery. The cNODE MiniS 1.11-50V Ti contains a custom made 58 Wh Li-Ion battery. • Product name: cNODE MiniS battery • Part number: 396782 •...
  • Page 39: Section 3: Composition

    Battery safety of compromising the enclosure. If this occurs, exposure to the electrolyte solution contained within can occur by inhalation, ingestion, eye contact and skin contact. The electrolyte solution would be corrosive and can cause irritation and burns. Other hazards •...
  • Page 40: Section 4: First Aid Measures

    MiniS 1.11-50V Ti Instruction Manual SECTION 4: First aid measures The battery will release toxic fumes if burned or exposed to fire. The battery will release toxic fumes if burned or exposed to fire. If subjected to gas from a burning battery, remove the source of contamination or move the victim to fresh air.
  • Page 41: Section 7: Handling And Storage

    Battery safety SECTION 7: Handling and storage Do not open, dissemble, crush or burn the battery. Do not open, dissemble, crush or burn the battery. Do not expose the battery to temperatures outside the range of -30 °C to 70 °C. Store in a dry location.
  • Page 42: Section 10: Stability And Reactivity

    Required battery state for transportation is 30% or less remaining capacity to comply with regulations. • Shipment of transponder Each cNODE MiniS 1.11-50V Ti is transported as a closed and sealed unit, and shall not be opened by unauthorized personnel. 436538/A...
  • Page 43: Section 15: Regulatory Information

    If the battery is shipped separately, the prevailing national regulations that apply are: UN No. 3480, Miscellaneous (Lithium Ion battery). For all shipments – cNODE MiniS 1.11-50V Ti and separate batteries –, use lithium battery handling label as specified in the additional requirement of Section II of packing instructions 965, 966 and 967.
  • Page 44 MiniS 1.11-50V Ti Instruction Manual Index 364845 physical and chemical properties ...... 41 TTC10 ............. 29 stability and reactivity........42 404199 toxicological information ....... 42 battery charger ........... 28 transport information ........42 407647 batterybatery safety test and configuration cable to TTC ....29 hazards identification........
  • Page 45 TTC ....29 introduction TTC10 ............. 29 TTC ............8 performance specifications ..........34 physical properties battery safety ..........41 Kongsberg Maritime pin out ............32 support ............ 10 power requirements ..........35 pre-deployment checks........16 procedure lubricating changing to responder mode ......
  • Page 46 MiniS 1.11-50V Ti Instruction Manual this manual..........5 weight ............. 35 TTC ............8 temperature requirements ..........36 test and configuration cable to PC 407648 ............ 29 spare part..........29 reactivity test and configuration cable to TTC battery safety ..........42 407647 ............
  • Page 48 ©2018 Kongsberg Maritime...