Installation - Zanussi ZFU25201WA User Manual

Table of Contents

Advertisement

Problem
Water flows on the floor.
Temperature cannot be set.
Door is misaligned or interferes
with ventilation grill.
The temperature in the appliance
is too low/too high.
If the advice does not lead to the
desired result, contact the nearest
Authorised Service Centre.
Closing the door
1. Clean the door gaskets.

Installation

WARNING!
Refer to Safety chapters.
Positioning
This appliance can be installed in a dry, well
ventilated indoor where the ambient
temperature corresponds to the climate class
indicated on the rating plate of the appliance:
10
Possible cause
The melting water outlet is not
connected to the evaporative
tray above the compressor.
The QuickFreeze or QuickChill
function is switched on.
The appliance is not levelled.
The temperature regulator is
not set correctly.
The food products' tempera-
ture is too high.
The door has been opened of-
ten.
The QuickFreeze function is
switched on.
There is no cold air circulation
in the appliance.
2. If necessary, adjust the door. Refer to
3. If necessary, replace the defective door
Climate
SN
N
ST
T
Attach the melting water outlet to
the evaporative tray.
Switch off QuickFreeze or Quick-
Chill manually, or wait until the
function resets automatically to set
the temperature. Refer to "Quick-
Freeze or QuickChill function".
Refer to "Levelling".
Set a higher/lower temperature.
Let the food products temperature
decrease to room temperature be-
fore storage.
Open the door only if necessary.
Refer to "QuickFreeze function".
Make sure that there is cold air cir-
culation in the appliance.
"Installation".
gaskets. Contact the Authorised Service
Centre.
Ambient temperature
class
+10°C to + 32°C
+16°C to + 32°C
+16°C to + 38°C
+16°C to + 43°C
Solution
www.zanussi.com

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents