Soft Start

Soft Start

"Soft Start" mode is provided to start the pump after a protracted
stop of the TwisTorr 304 FS. This allows a better grease distribution
in the bearings.
The "Soft Start" mode is disabled by default.
To enable the "Soft Start" mode it must be activated by the suitable
software or Remote I/O command (see Controller Manual).
"Soft Start" frequency steps are as follow: 300 Hz, 400 Hz, 800 Hz, 900
Hz. For more details see Controller Manual.