4.13) Cancelling all radio controls
This procedure cancels all the radio controls saved in the memory.
Table 25
Cancelling all radio controls
1.
Hold down the 'Cancel radio control' key for about 3 seconds until the respective LED
starts flashing.
2.
The green OK LED starts flashing: press OK within 3 seconds to confirm.
4.14) Copying parameters and radio controls
By using a combination of keys, it is possible to read the parameters and radio controls of a motor and save them in the memory of the TTP
programmer. This data can then be transferred to other motors of the same type.
4.14.1) Reading the motor parameters
To read the parameters, proceed as described in Table 26.
!
In order to prevent accidental cancellation or overwriting of the TTP memory, the motor parameter reading procedure can
only be executed if the TTP memory has been previously cancelled by means of the appropriate procedure (see Table 28).
Table 26
Motor parameter reading
1.
Press the "READ PARAMETERS" key.
2.
Press one or more keys ("F1", "F2", "F3") according to the data you want to copy:
• F1 reads the parameters for direction of rotation and travel limits
• F2 reads the parameters for sensors (wind and sun thresholds, etc.)
• F3 reads the radio controls
3.
The green OK LED starts flashing: press OK within 3 seconds to confirm.
4.14.2) Writing parameters to the motor
To transfer the previously saved parameters, proceed as described in Table 27.
Table 27
Transferring parameters to the motor
1.
Press the "WRITE PARAMETERS" key.
2.
Press one or more keys ("F1", "F2", "F3") according to the data you want to programme:
• F1 enters the parameters for direction of rotation and heights
• F2 enters the parameters for the sensors
• F3 enters the radio controls
3.
The green OK LED starts flashing: press OK within 3 seconds to confirm.
!
The parameters can be transferred only if the motor is of the same type as the motor which has been read.
4.14.3) Cancelling parameters memorized in the TTP memory
To cancel parameters saved in the TTP memory, proceed as described in Table 28.
Table 28
Cancelling the TTP memory
1.
Press the "CANCEL PARAMETERS" key.
2.
Press the keys "F1", "F2" and "F3" in sequence
3.
The green OK LED starts flashing: press OK within 3 seconds to confirm.
10
Example
3s
3s
Example
3s
Example
3s
Example
3s