Timed Cycles
When running a Timed cycle the Cycle time is set by the user by touching the More and Less Keys from the User
Interface.
During the Timed cycle the dryer will run the temperature control algorithm and the timer until the remaining time
is 0:00.
Steam Cycles
The steam cycles (Aerosteam and Aerosteam Plus) switch between heat and steam by fixed time periods, which
are described below:
Steam
Heat
Steam
Heat
Steam
Heat
Steam
Heat
Cooldown
Wrinkle Free
After completion of the drying cycle the drum will rotate (with no heat) 30 seconds and will be paused for 5
minutes to prevent wrinkling or creasing of clothes for up to 24 hours or until the power is turned off, start/pause
pressed or open the door.
Delay Start
When the delayed start button is selected the display will change to show to 0 minutes. This delay time period
can then be adjusted up and down using the "+" and "-" buttons below the display. The delay time will increment
in 5 min, 15 min , 30 min 1 hr and then in 1 hour steps up to 12 hours. The dryer will rotate the drum with no
heat for 30 seconds every 15 minutes to reduce risk of dye transfer until the cycle starts.
1.1.3
Element Operation (Electric Models)
The element circuit has three thermostats and has a motor switch to stop the heating if the motor should fail.
Power is supplied to line L1 both to control board and one of the terminals of the control relays (Inner coil, Outer
coil, Mist valve and Drum).
Power supply is connected to Inlet Safety Thermostat and Outlet Backup Thermostat. If any those thermostats
are open due to an abnormal temperature decrease, both Inner and outer coils shall switch off and the dryer will
continue the drying cycle. Both coils will switch on when the thermostats close its terminals.
The Hi-limit thermostat Power off the unit when is detected an abnormal temperature decrease.
Fisher&Paykel
Electric model*
Aerosteam
Aerosteam
Plus
180
120
60
90
120
120
30
30
120
120
30
30
420
450
120
60
*Time in seconds
- 53 -
Gas model*
Aerosteam
Aerosteam
Plus
180
150
60
90
150
150
30
30
150
150
30
30
450
480
120
60