Appendix; Cold Start Procedure; Version - Netafim NMC-64 User & Installation Manual

Table of Contents

Advertisement

User & Installation manual

Appendix

Cold Start procedure

Cold Start resets the NMC-64 to the original factory settings. This procedure should be
performed after replacing a software version, when reinstalling the controller or when
instructed by Netafim technician.
To perform a cold start:
1. Disconnect the NMC-64 power supply.
2. Turn power on, press and hold the delete key until cold start pop-up
screen appears.
3. If you choose No, the NMC-64 will continue to its usual power up
procedure; settings will remain untouched.
4. if you choose Yes NMC-64 will perform cold start procedure; controller
will start with Ram and EPROM cleaning procedure. All controller
settings will be erased and restored back to default factory settings. All
history will be erased.
5. After cold start procedure has ended NMC-64 will return to the main
screen; to use NMC-64 controller start installation from beginning.
It is recommended to save NMC-64 settings to Data-plug and / or PC
before starting the cold start procedure. This will enable to restore previous
settings and setup if required.

VERSION

To check controller version enter the main screen and press the Help button. To exit
the Version screen press the Enter key.