Agitator; Selector - Netafim NMC-64 User & Installation Manual

Table of Contents

Advertisement

NMC-64 Irrigation
Notice that the Start Dry Contact doesn't necessarily have to open and close in
order to initiate another irrigation, is simply has to be closed when the irrigation
has finished.
3. Only If On - the associated Irrigation program will be turned on providing the
Start Dry Contact has been closed for more than 20 second and will remain on
as long as the contact is closed.
• Stop Dry Con. – Set the dry contact number for stoping the irrigation. Since the
Stop Dry Contact is "stronger" than the Start Dry Contact the associated irrigation
program will not be started as long as the Stop Dry Contact is closed.

1.5 AGITATOR

The agitator is used to mix the fertilizers and acid in the storage tanks in order to
prevent the occurrence of sediment.
Dosing Active
Dosing Not Active
• Dosing Active – definition of the On and Off times of the agitator when dosing is
taking place:
• On – Define the required mixing time.
• Off – Define the required time between mixing.
• Dosing Not Active - definition of the On and Off times of the agitator when dosing
is not taking place:
• On – Define the required mixing time.
• Off – Define the required time between mixing.

1.6 SELECTOR

Enables the use of various fertilizer stock tanks. Every Fertilizer Program can be
connected to one (or more) selectors output, using these outputs you can choose
which storage set will be connected to each Fertilizer Program.
AGITATOR
On
mm:ss
01:00
02:00
26
Off
mm:ss
10:00
30:00

Hide quick links: