The EC/pH columns will not be visible if EC/pH control is marked 'No' in
menu
7.7 DOSING

1.4 CONDITION

Condition program enables to start and / or stop irrigation according to dry contacts.
From
#
hh:mm
1
08:00
2
06:00
3
09:00
4
--:--
5
--:--
6
--:--
7
--:--
8
--:--
9
--:--
• From (hh:mm) – Set the start time of the condition program.
• To (hh:mm) – Set the end time of the condition program
The condition program will only be operative in the defined window of opportunity
(between start "From" to end "To" times). Each condition program can be operative
on different hours.
• Start Dry Con. – Set the dry contact number for starting the irrigation.
• Trigger Type – Choose one of three trigger types:
1. One Shot – if the Start Dry Contact is closed for more than 20 seconds the
associated irrigation program will be started. The contact must open and close
to initiate another irrigation.
2. Multi shot – if the Start Dry Contact is closed for more than 20 seconds the
associated irrigation program will be started. If the contact is still closed when
the irrigation has finished another irrigation will be initiated.
CONFIGURATION.
CONDITION PROGRAM
To
Start
hh:mm
Dry Cont.
16:00
Dry Con 1
20:00
Dry Con 4
18:00
Dry Con 1
--:--
<NONE>
--:--
<NONE>
--:--
<NONE>
--:--
<NONE>
--:--
<NONE>
--:--
<NONE>
25
Trigger
Stop
Type
Dry Cont.
One Shot
Dry Con 2
Multi Shot
------
Only If On
------
One Shot
<NONE>
One Shot
<NONE>
One Shot
<NONE>
One Shot
<NONE>
One Shot
<NONE>
One Shot
<NONE>
Software