If you want to do other configurations please refer to below programming barcodes. Barcode Programming Netum barcode scanners are factory programmed for common terminal and communications settings. If you need to change these settings, programming is accomplished by scanning the bar codes in this guide.
USB Serial Port Driver is required if you want to work under USB Serial Port. Please download it from below link http://www.gzxlscan.com/downloads/ For Win 7,install 64X, for other system please install X86. As for system above Win 10 no need to install any software.
Newly Added Hungary Keyboard Czech Keyboard Scanning Mode · Key Holding Press the button to trigger the reading, release the button to end the reading. Reading success or reading time over a single reading time will end the reading Level * Continuous Mode ·...
Disable CR & LF* Beeper Volume To select a decode beep volume, scan the appropriate bar code. Medium High Mute To enable or disable close all prompt, scan the appropriate bar code below. Disable Enable...
Default Configuration If you want to cancel all the configuration that you have done to the scanner. Scan below barcodes to the restore factory. Transmit Code ID Character A code ID character identifies the code type of a scanned bar code. This can be useful when decoding more than one code type.
Common Function Enable/Disable UPC-A To enable or disable UPC-A, scan the appropriate bar code below. *Enable UPC-A Disable UPC-A Enable/Disable UPC-E To enable or disable UPC-E, scan the appropriate bar code below. *Enable UPC-E Disable UPC-E Enable/Disable EAN-8 To enable or disable EAN-8, scan the appropriate bar code below. *Enable EAN-8 Disable EAN-8 Enable/Disable EAN-13...
Enable/Disable Bookland EAN(ISBN) To enable or disable EAN Bookland, scan the appropriate bar code below. Enable Bookland EAN *Disable Bookland EAN Decode UPC/EAN Supplementals Supplementals are bar codes appended according to specific format conventions (e.g.UPC A+2, UPC E+2, EAN 13+2, EAN 13+5). The following options are available: *Ignore UPC/EAN with Supplementals Do not read supplementals –...
Transmit UPC-A Check Digit Scan the appropriate bar code below to transmit the symbol with or without the UPC-A check digit. *Transmit UPC-A Check Digit Do Not Transmit UPC-A Check Digit Transmit UPC-E Check Digit Scan the appropriate bar code below to transmit the symbol with or without the UPC-E check digit. *Transmit UPC-E Check Digit Do Not Transmit UPC-E Check Digit Convert UPC-E to UPC-A...
Enable/Disable Code 39 Full ASCII Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set. To enable or disable Code 39 Full ASCII, scan the appropriate bar code below. See Table 4-3 for the mapping of Code 39 characters to ASCII values. Enable Code 39 Full ASCIl *Disable Code 39 Full ASCII NOTE Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously.
Interleaved 2 of 5 Enable/Disable Interleaved 2 of 5 To enable or disable Interleaved 2 of 5, scan the appropriate bar code below. *Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 Transmit I 2 of 5 Check Digit Scan this symbol to transmit the check digit with the data.
Page 12
Matrix 25 Enable/Disable Matrix 25 To enable or disable Matrix 25, scan the appropriate bar code below. Enable Matrix 25 *Disable Matrix 25 Transmit Matrix 25 Check Character Enable Matrix 25 Transmit Check Character Disable Matrix 25 Transmit Check Character * Codabar Enable/Disable Codabar To enable or disable Codabar, scan the appropriate bar code below.
Page 13
Transmit MSI Check Digit (Enable) Scan this symbol to transmit data without the check digit. *Do Not Transmit MSI Check Digit (Disable) GS1 DataBar/RSS Enable/Disable GS1 DataBar-14 To enable or disable GS1 DataBar-14, scan the appropriate bar code below. Enable GS1 DataBar-14 *Disable GS1 DataBar-14 Enable/Disable GS1 DataBar Limited To enable or disable GS1 DataBar Limited, scan the appropriate bar code below.
PDF417 Enable/Disable PDF417 To enable or disable PDF417, scan the appropriate bar code below. Disable PDF417 *Enable PDF417 Enable/Disable QR To enable or disable QR, scan the appropriate bar code below. Disable QR Code *Enable QR Code Data Matrix(DM) Enable/Disable Data Matrix(DM) To enable or disable Data Matrix(DM), scan the appropriate bar code below.
Page 15
and Suffixes Via Serial Commands. NOTE In order to use Prefix/Suffix values, the Scan Data Transmission Format must be set. Scan Prefix Scan Suffix 1 Scan Suffix 2 Scan Data Transmission Format To change the Scan Data Transmission Format, scan one of the eight bar codes corresponding to the desired format.
Page 16
<PREFIX> <DATA> <SUFFIX 2> <PREFIX> <DATA> <SUFFIX 1> <SUFFIX 2> Enable /Disable Functional Key Set Disable Functional Key Set* Enable Functional Key Set For example if you scan value 1004, Keystroke will be “Up Down”. But if you scan Enable Functional Key Set after you scan the value ” 1004”, you will get functional key set Ctrl +D.
Page 18
Example on how to set prefix and suffix Prefix Setting Step 1: scan prefix Scan Prefix...
Page 19
Step 2: To set these values, scan a four-digit number (i.e. four bar codes) that corresponds to ASCII values. See the Table 4-3 and Numeric Bar Codes in appendix. Step 3: i.e if you want to add “+” , scan 1043 (one by one) Step 4: Set Data Transmission Format <PREFIX>...
Page 20
Setting Prefixes and Suffixes Via Serial Commands To append a prefix and suffixes to the decode data: 1、Set the Scan Data Transmission Format (parameter 0xE2) to the desired option. 2、Enter the required value(s) for Prefix (0x69), Suffix1 (0x68) or Suffix2 (0x6A) using the hex values for the desired ASCII value from Table 4-3 Table 4-3 Character Equivalents (Continued) Full ASCLL Code...
Page 21
Table 4-3 Character Equivalents (Continued) Full ASCLL Code Scan Value Hex Value Keystroke Full ASCLL Code 39 Encode Char Scan Value Keystroke 39 Encode Char CTRL Y 1025 1026 CTRL Z CTRL [ 1027 1028 CTRL \ 1029 CTRL ] CTRL 6 1030 1031...