Section 4. Start-Up And Operation; New Pool And Seasonal Start-Up; Section 5. Filter Disassembly And Assembly; Filter Element Removal - Jandy CS100 Installation And Operation Manual

Pro series. single element cartridge pool & spa cs filters
Table of Contents

Advertisement

Available languages

Available languages

Page 8
ENGLISH

Section 4. Start-Up and Operation

WARNING
NEVER start pump while standing
within five (5) feet of the filter. Starting
the pump while there is pressurized
air in the system can cause product
failure or also cause the filter lid to
be blown off, which can cause death,
serious personal injury or property
damage.
WARNING
NEVER operate the filter system at
more than 50 psi of pressure. Operating
the filter system in excess of 50 psi can
cause product failure or also cause
the filter lid to be blown off, which can
cause death, serious personal injury or
property damage.
CAUTION
DO NOT operate filter at water temperatures above
105° F (40.6° C). Water temperatures above the
manufacturer's recommendations will shorten the life
span of the filter and void the warranty.
4.1

New Pool and Seasonal Start-up

1.
Turn off the filter pump and switch off the circuit
breaker to the pump motor.
2.
Check that the filter drain cap and nut are in place
and tight.
3.
Check that the tank locking ring is properly seated
and tight.
4.
Open the pump hair/lint pot lid and fill the pump
basket with water to prime the system. Replace
the pump lid. You may have to do this a few times
on new and seasonal start ups.
5.
Open the air release valve on top of the filter (do
not remove the valve).
6.
Be sure to open any isolation valves that were
installed in the system.
7.
Stand clear of the filter and start the pump to
circulate water through the system. When all the
air is bled from the system and a steady stream of
water starts to come out of the air release valve,
close the valve.
8.
Watch the pressure gauge to be sure that the pressure
does not exceed 50 psi. If the pressure approaches
50 psi, immediately turn the pump off and clean the
filter cartridges. If the pressure remains high after
cleaning the filter, refer to the troubleshooting guide,
Section 8, for possible causes and solutions.
Jandy
Pro Series, CS Single Element Cartridge Pool & Spa Filter
®
9.
Figure 5.
Section 5. Filter Disassembly
5.1
1.
2.
3.
4.
After the pressure gauge has stabilized, turn the
bezel ring so that the arrow next to the word
"CLEAN" aligns with the needle of the gauge.
See Figure 5. As the filter cleans the water, and
the cartridges begin to clog the pressure begins to
increase. When the needle of the pressure gauge
aligns with the arrow next to the word "DIRTY"
on the bezel, it is time to clean the filter, see
Section 6.3. This indicates an increased pressure
of between 10 and 12 psi above original starting
pressure.
Pressure Gauge with Clean/Dirty Snap
Ring
and Assembly
WARNING
NEVER attempt to assemble,
disassemble or adjust the filter when
there is pressurized air in the system.
Starting the pump while there is any
pressurized air in the system can
cause product failure or also cause
the filter lid to be blown off, which can
cause death, serious personal injury or
property damage.

Filter Element Removal

off
Turn
the filter pump and switch off the circuit
breaker to the pump motor.
Open air release valve on top of the filter tank
to release all pressure from inside the tank and
system, see Fig. 6. Close any filter isolation
valves on the system to prevent flooding.
Open the filter tank drain. When the filter tank has
drained, close the drain.
Remove the locking ring/tank top assembly by
pushing on the locking tab and turning the lock
ring counterclockwise.
|
Installation & Operation Manual