Wiring
To wire the CLS-EXP-DIMFLV, remove the cover and make the connections.
WARNING: RISK OF SERIOUS PERSONAL INJURY. Turn off power at the circuit
breaker(s) prior to installation. Installing with the power on can result in serious personal
injury and damage to the device.
Remove the Cover
Use a #2 Phillips screwdriver to remove the cover screws and then the cover.
Remove Cover Screws
Cover
screws
This product is Listed to applicable UL
®
Standards and requirements tested by Underwriters
Laboratories Inc.
Ce produit est homologué selon les normes et les exigences UL applicables par Underwriters
Laboratories Inc.
Federal Communications Commission (FCC) Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions:
(1) This device may not cause harmful interference and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Make the Connections
There are seven captive screw terminals on the CLS-EXP-DIMFLV that allow power input,
power output, and load control.
NOTE: Observe the following points:
• Strip wires to 7/16 in (12 mm).
• Tighten terminal screws to 7 in-lbs (0.79 Nm).
• Captive screw terminals accept up to two 22 to 12 AWG (0.34 to 4 mm
terminal.
• Dimmer channels controlling one or more CLS-EXP-DIMFLV modules must not be
wired to control any other type of load.
• While these diagrams show a CLS-C6 as the controlling source, other Crestron
products such as CLW-series wall dimmers (Cresnet
and infiNET™ dimmers) and
®
CLX-series dimming modules can be used as well. Refer to "CLS-EXP-DIMFLV
Specifications" on page 1 for details.
• Use a neutral wire for a CLW-Series wall dimmer.
• Use 75°C copper wire only.
• The CLS-EXP-DIMFLV presents a 25 W load to the controlling dimmer. A maximum
of five CLS-EXP-DIMFLV modules may be connected to the controlling dimmer,
which cannot be wired to control any other loads besides the CLS-EXP-DIMFLV
modules.
• Separate Class 1 and Class 2 wires. When wiring a 0-10 V fluorescent dimmer, the
+ and – make connections using Class 1 or Class 2 wiring. If Class 1 wiring is used,
the barrier between the NEUT and + terminals can be removed.
Wire the CLS-EXP-DIMFLV for a 0-10 V dimming or a switching application.
CLS-EXP-DIMFLV Wiring for 0-10 V Dimming
Hot
(120 to 277 Vac)
Neutral
LOAD 3
Hot
LOAD 2
(120 to 230 Vac)
CLS(I)-C6
LOAD 1
HOT
NEUTRAL
Neutral
0-10 V uorescent
dimming ballast
CLS-EXP-DIMFLV Wiring for Switching Application
Hot
(120 to 277 Vac)
Neutral
LOAD 3
Hot
LOAD 2
(120 to 230 Vac)
CLS(I)-C6
LOAD 1
HOT
NEUTRAL
Neutral
Switched load
After wiring is complete, replace the cover and the cover screws. Apply power to the line or
load and turn on the controlling device. The power indicator LED lights indicating that power
is supplied to the module.
CAUTION: Changes or modifications not expressly approved by the manufacturer responsible for
compliance could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
Problem Solving
The following table provides corrective action for possible trouble situations. If further
assistance is required, please contact a Crestron customer service representative.
CLS-EXP-DIMFLV Troubleshooting
Trouble
Possible Cause(s)
The load does not turn on.
The controlling dimmer or
2
) wires per
switch is not working.
No power is applied to the
HOT terminal.
The load turns on and off
The controlling unit is either
but does not dim.
not a dimmer or has been
set to non-dim.
The lights do not dim
An incompatible dimmer is
properly.
being used.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV technician for help.
The product warranty can be found at www.crestron.com/warranty.
The specific patents that cover Crestron products are listed at patents.crestron.com.
Certain Crestron products contain open source software. For specific information, please visit
www.crestron.com/opensource.
Crestron, the Crestron logo, Cresnet, iLux, and infiNET are either trademarks or registered trademarks
of Crestron Electronics, Inc. in the United States and/or other countries. Crestron and the Crestron logo
are either trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/
Corrective Action
Make sure that the
controller is powered on.
Make sure that a
compatible dimmer is being
used.
Check the circuit breaker.
Check that the green power
LED inside the unit is lit.
Verify that dimmer is
compatible with the
CLS-EXP-DIMFLV. Refer
to "CLS-EXP-DIMFLV
Specifications" on page 1.
Verify that the controlling
channel has not been
programmed as non-dim.
Make sure that the dimmer
is one of those listed
in "CLS-EXP-DIMFLV
Specifications" on page 1.
or other countries. UL and the UL logo are either trademarks or registered trademarks of Underwriters
Laboratories, Inc. in the United States and/or other countries. Other trademarks, registered trademarks,
and trade names may be used in this document to refer to either the entities claiming the marks and
names or their products. Crestron disclaims any proprietary interest in the marks and names of others.
Crestron is not responsible for errors in typography or photography.
This document was written by the Technical Publications department at Crestron.
©2017 Crestron Electronics, Inc.
Crestron Electronics, Inc.
15 Volvo Drive Rockleigh, NJ 07647
Tel: 888.CRESTRON
Fax: 201.767.7576
www.crestron.com
Installation Guide - DOC. 6680C
(2020652)
07.17
Specifications subject to
change without notice.

Advertisement

loading
Need help?

Need help?

Do you have a question about the CLS-EXP-DIMFLV and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel