ABB REM615 ANSI 5.0 FP1 Product Manual page 9

Motor protection and control
Table of Contents

Advertisement

Table 2. Supported functions (continued)
Function
Control
Earthing switch indication
Emergency startup
Conditioning monitoring and supervision
Circuit breaker condition monitoring
Trip circuit supervision
Current circuit supervision
Fuse failure supervision
Runtime counter for machines and devices
Measurement
Load profile record
Three-phase current measurement
Sequence current measurement
Residual current measurement
Three-phase voltage measurement
Residual voltage measurement
Sequence voltage measurement
Single-phase power and energy measurement
Three-phase power and energy measurement
RTD/mA measurement
Frequency measurement
IEC 61850-9-2 LE
sampled value sending 23), 26)
IEC 61850-9-2 LE
sampled value receiving (voltage sharing) 23), 26)
Other
Minimum pulse timer
(2 pcs)
Minimum pulse timer (2 pcs, second resolution)
Minimum pulse timer (2 pcs, minute resolution)
Pulse timer (8 pcs)
Time delay off (8 pcs)
Time delay on (8 pcs)
Set-reset (8 pcs)
Move (8 pcs)
Generic control point (16
pcs)
Analog value scaling
(4 pcs)
Integer value move
(4 pcs)
Generic up-down counters
() = optional
1) One of the following can be ordered as an option; Admittance based E/F, Wattmetric based E/F or Harmonics based E/F. The option is an addition to the existing E/F of the
original configuration. The optional E/F has also a predefined configuration in the relay. The optional E/F can be set on or off.
2) Multi-purpose protection is used for, for example, RTD/mA based protection, or Analogue Goose
3) Light only
4) Io selectable by parameter, Io measured as default
5) Io selectable by parameter, Io calculated as default
6) Io calculated is always used
7) IoB calculated is always used
8) IoB calculated and 3IB are always used
9) Uo selectable by parameter, Uo measured as default
10) Uo calculated and negative sequence voltage selectable by parameter, Uo calculated as default
11) Uo calculated is always used
12) Uo measured is always used
13) IoB measured is always used
IEC 61850
ANSI
A
ESSXSWI
29GS
2
ESMGAPC
62EST
1
SSCBR
52CM
1
TCSSCBR
TCM
2
CCSPVC
CCM
1
SEQSPVC
60
MDSOPT
OPTM
1
LDPRLRC
LOADPROF
1
CMMXU
IA, IB, IC
1
CSMSQI
I1, I2, I0
1
RESCMMXU
IG
1
VMMXU
VA, VB, VC
RESVMMXU
VG
VSMSQI
V1, V2, V0
SPEMMXU
SP, SE
PEMMXU
P, E
XRGGIO130
X130 (RTD)
(1)
FMMXU
f
SMVSENDER
SMVSENDER
SMVRCV
SMVRECEIVER
TPGAPC
62TP
1
3
TPSGAPC
62TPS
1
TPMGAPC
62TPM
1
PTGAPC
62PT
2
TOFGAPC
62TOF
4
TONGAPC
62TON
4
SRGAPC
SR
4
MVGAPC
MV
2
SPCGAPC
SPC
2
SCA4GAPC
SCA4
4
MVI4GAPC
MVI4
1
UDFCNT
CTR
4
B
D
(19)
2
(19)
1
1
(19)
1
1
1
1
2
2
1
1
1
1
(19)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
(1)
1
1
(1)
(1)
(1)
(1)
3
3
(19)
1
(19)
1
(19)
1
1
(19)
1
(19)
1
(19)
2
2
(19)
(19)
(19)
4
4
(19)
(19)
(19)
4
4
(19)
(19)
(19)
4
4
(19)
(19)
(19)
2
2
(19)
(19)
(19)
2
2
(19)
(19)
(19)
4
4
(19)
(19)
(19)
1
1
(19)
(19)
(19)
4
4
(19)
(19)
(19)
9
E
1
1
(19)
1
1
2
1
1
(19)
1
1
2
1
1
1
1
1
1
1
1
(1)
(1)
3
1
(19)
1
1
(19)
2
(19)
4
(19)
4
(19)
4
(19)
2
(19)
2
(19)
4
(19)
1
(19)
4
(19)