Specific Notes - UMS T5 User Manual

Pressure transducer tensiometer
Table of Contents

Advertisement

Introduction
1.6.5

Specific notes

T5 and T5x are not suitable for dry soils and they are not frost
resistant.
When installed in the field provide sufficient protection.
The less air is inside the cup and the better the soil's conductivity
is, the faster the Tensiometer will respond to tension changes.
It does not make sense to refill a Tensiometer as long as the soil
is dryer than -90 kPa (T5) or - 160 kPa (T5x).
Using a quartz clay slurry is only recommendable in clayey soils
and only if the drilled diameter is larger than the shaft diameter
(5 mm). In coarse sand or gravel soil a fine grained slurry paste
would act as a water reservoir which would lead to a slower
response.
The T5 can be installed in any position and orientation. Bubbles
are easily detectable through the transparent shaft.
Output signals are standardized.