Fujitsu ETERNUS DX Configuration Manual page 24

Server connection, fcoe for vmware esx driver settings for non-fujitsu converged network adapter cards
Hide thumbs Also See for ETERNUS DX:
Table of Contents

Advertisement

Chapter 2
Setup Procedure for QLogic Converged Network Adapter Cards
2.2
Setting Up the Converged Network Adapter Cards
The procedure is as follows:
1
Install the Converged Network Adapter card in the server.
For the installation method, installable PCI bus slot position, activation of the installed slot, and notes
regarding the Converged Network Adapter card, refer to the Converged Network Adapter card documen-
tation or the User's Guide of the server.
2
Turn on the server, and press the [Ctrl] + [Q] keys while the following message is displayed.
QLE8142
Copyright (C) QLogic Corporation 1993-2010. All rights reserved.
www.qlogic.com
Press <CTRL-Q> or <ALT-Q> for Fast!UTIL
Firmware Version 5.04.01
The "Fast!UTIL" program starts up (Startup may take longer than usual).
3
Check the value of [Address] of the [Selected Adapter] window.
The value of [Address] is the physical address.
Adapter Type
QLE8142
4
Select [Adapter Settings] from the [Configuration Settings] menu and press the [Enter] key.
5
Check the value of [Adapter Port Name].
The value of [Adapter Port Name] is the Converged Network Adapter card WWN.
BIOS Address:
BIOS Revision:
Adapter Mac Address:
Interrupt Level:
Adapter Port Name:
Host Adapter BIOS:
6
Record the physical address and WWN in the "WWN instance management table for the server".
(found in
The following shows an example of this.
Host name
IP Address
Physical slot
name
slot5
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (FCoE) for VMware
PCI Fibre Channel ROM BIOS Version 3.00 - Beta 14
Selected Adapter
Address
Slot Bus Device Function
5800
05
04
Adapter Settings
D1800
3.00
00-C0-DD-11-A0-21
9
210000C0DD11A021
Enabled
"Appendix A WWN Instance Management Table for the Server (Blank)" (page
Server#1
192.168.0.10
Converged Network Adapter
card WWN
21 00 00 C0 DD 11 A0 21
Copyright 2015 FUJITSU LIMITED
00
2
Instance name
Physical address
5800
24
33)).
Cable tag
SERV1_SLOT05 to B8000_1_port05
®
ESX
P3AM-4772-11ENZ0