higher than 254 Vac presents the message 0.
Function available for model N322T-NTC-LVD.
Set Point - Temperature adjustment for control. SP value is limited to the values
SP
programmed in SPL and SPk in the programming level.
heating systems, program ont to zero. Value in seconds, 0 to 999 s.
Delay - Delay time to start control. Upon power-on, control OUTPUT 1 is kept
dly
off until the time programmed in dly is elapsed. Its usage is intended to
prevent multiple compressors to start simultaneously after the turn-on of a
system with several controllers. Value in seconds, 0 to 250 s.