SYSTEM CONFIGURATION PROCEDURE
7.1.1 Example of Device Startup & Shutdown Order
1:30
1:00
• Startup: According to the settings above, the pump will be turned on first (on procedure startup). The main
valve will be opened after 1 minute later (one minute from procedure startup) the valve.
• Shutdown: According to the settings above the valve will be turned off first (on procedure shutdown). The
main valve will be closed after 15 seconds and the pump will be closed 20 seconds later (35 seconds from
procedure shutdown).
Note: It is recommended that the device that should be started (stopped) first be defined as zero
(will appear as --:--).
• Shift delay (sec): Define the time (in seconds) between each valve change. The shift delay can also be a
shift advance by inserting a negative value. This means that the next valve will start before the previous one.
• Stagger delay (sec): Define the time (in seconds) for the first shift and the last shift delay between valves
(inside of group).
Stagger
VALVE 2
00:20
VALVE 1
MAIN
PUMP
IN-PROGRAM DELAYS
Stagger
00:20
0:15
00:35
mm:ss