Download Print this page

Netafim EFLOW CNL XR Installation Manual

Water reuse dispersal system

Advertisement

Quick Links

EFLOW
INSTALLATION
GUIDE
WATER REUSE DISPERSAL SYSTEM

Advertisement

loading

Summary of Contents for Netafim EFLOW CNL XR

  • Page 1 EFLOW INSTALLATION GUIDE WATER REUSE DISPERSAL SYSTEM...
  • Page 2 DRIPPERLINE: DRIPPERLINE: DRIPPERLINE: Netafim Unibioline CNL XR Netafim Unibioline AS XR Netafim Unibioline CNL Flow rate: 1.6 L/Hr Flow rate: 1.6 L/Hr Flow rate: 1.6 L/Hr Spacing: 0.4m Spacing: 0.5m...
  • Page 3 HOW THE EFLOW SYSTEM WORKS Netafim’s EFlow dripperline system delivers a slow and precise application of treated effluent evenly throughout the soil. Made of flexible polyethylene tubing, the dripperline has evenly spaced pre-inserted emitters. When water is pumped through the dripperline, these pressure compensating emitters discharge an even, slow distribution of treated effluent into the ground.
  • Page 4: Surface Installation

    INSTALLATION GUIDE UNIBIOLINE DRIPPERLINE FLUSHING VALVE EXISTING ON-SITE EFFLUENT TREATMENT AIR RELEASE VALVE DISC FILTER & TECHFILTER *WHERE APPLICABLE SURFACE INSTALLATION SUB SURFACE - TRENCHING SURFACE INSTALLATION SUB-SURFACE DRIPPERLINE INSTALLATION TECHNIQUES Surface Installations apply the same principles as sub-surface There are a number of techniques you can use when installing Installations except they are not buried.
  • Page 5 SUB SURFACE - TRENCHING SUB SURFACE - VIBRATORY PLOUGH SUB SURFACE - RIPPING SURFACE - BACKFILLING SUB-SURFACE DRIPPERLINE INSTALLATION TECHNIQUES (CONTINUED) TRENCHING VIBRATORY PLOUGH This is the most common technique. This involves digging a The vibratory plough is more suitable for larger sites with longer trench no wider than 50mm to the depth required.
  • Page 6: Filter Assembly

    A Techfilter is not required for 2. Attach the 25mm End Connectors to the end of the header EFlow CNL XR and EFlow AS XR kits. assembly using a 25mm ratchet clamp. 1. Assuming the outlet of the treatment plant is a 25mm male 3.
  • Page 7: Maintenance And Servicing

    AIR VACUUM VALVE MAINTENANCE AND SERVICING This component is designed to release air from inside the Regular maintenance and servicing should be carried out dripperline during system start-up and shut-down. This reduces periodically. The following parts require on-going servicing to the potential risk of soil being sucked into the drippers and ensure the longevity of your EFlow system.
  • Page 8 EFLOW START-UP KIT CONTENTS EFLOW CNL XR START-UP KIT Standard Ki t 200M Unibioline CNL XR 1.6L/Hr Flow Rate 0.4m Spacing CNL XR & AS XR Kits EFLOW AS XR START-UP KIT 200M Unibioline AS XR 1.6L/Hr Flow Rate 0.5m Spacing...
  • Page 9 EFLOW ADD ON KIT CONTENTS EFLOW CNL XR ADD ON KIT 200M Unibioline CNL XR 1.6L/Hr Flow Rate 0.4m Spacing EFLOW AS XR ADD ON KIT 200M Unibioline AS XR 1.6L/Hr Flow Rate 0.5m Spacing EFLOW ADD ON KIT (NON-XR) 200M Unibioline CNL 1.6L/Hr Flow Rate 0.4m Spacing...
  • Page 10 GRAVEL/SAND SANDY LOAMS LOAMS CLAY LOAM LIGHT CLAYS MEDIUM/HEAVY CLAY SOIL TEXTURE SOIL STRUCTURE DISPERSAL RATE AREA REQUIRED DRIPPER LENGTH WEEKLY DAILY 1L/DAY 0.5M SPACING 1.0 SPACING GRAVEL/SAND Structureless Massive 5.00 SANDY LOAMS Weakly Structured 5.00 SANDY LOAMS Massive 5.00 LOAMS Highly / Moderately Structured 4.00...
  • Page 11 Any technical information is generic and should not be relied on by the reader or recipient. Furthermore, Netafim does not warrant or make any representation regarding the information contained in this manual or the reliability of the information and the reader or recipient should not rely upon any statement or representation made in this manual.
  • Page 12 GROW MORE WITH LESS ® WWW.NETAFIM.COM.AU WWW.NETAFIM.CO.NZ GROW MORE WITH LESS ® EFlow Kit Installation Guide EFLOW KIT INSTALLATION GUIDE December 2017 DECEMBER 2017...

This manual is also suitable for:

As xr eflowEflow