Circuit diagrams
7.2 Typical circuits
Table 7- 12
Typical circuit 12: 2 x single-channel, without cross-circuit detection, with monitored start
Table 7- 13
Typical circuit 13: 2x single-channel, without cross-circuit detection, with autostart
Also possible: 2 x single-channel with T1-IN1, T2-IN2 and DIP switch 2 cross-circuit
detection to ON.
128
Monitored start
Without cross-circuit detection
2 x single-channel
Sensor: two single-channel NC sensors
3SK1112 Standard solid-state and
3SK112/3SK122 Advanced
DIP switch
1
2
ON
OFF
right
left
Up to PL in accordance with ISO
13849-1
Up to Safety Integrity Level (SILCL) to
IEC 62061
Autostart
Without cross-circuit detection
2 x single-channel
Sensor: two single-channel NC contacts
3SK1112 Standard solid-state and
3SK112/3SK122 Advanced
DIP switch
1
2
OFF
OFF
left
left
Up to PL in accordance with ISO
13849-1
Up to Safety Integrity Level (SILCL) to
IEC 62061