QUICK GUIDE TO
Before starting the installation procedure, read carefully
FIRST POWER UP
through the installation and programming manuals.
1
Attach to the wall the
FLEX5
+ D S -
expansion
control panel enclosure and
the open tamper (optional)
Air2-BS100
transceiver
2
Connect the peripherals
to the BUS.
3
Connect the BUS
to the control panel.
JOY
Keypad
4
Set the balancing
parameters of the
system detectors.
OPEN-COLLECTOR OUTPUT
CONNECTION
5
Connect the
system detectors
Generic load
SmartLiving
to the terminals.
12V
control panel
+12V
+AUX
6
Connect the outputs
to the control panel and
peripheral terminals.
7
Connect the telephone
line to the control panel.
9
8
Connect the
SmartLogos30M to
the motherboard (PCB).
Strip connector
for the
maintenance jumper
9
Insert the
maintenance jumper
Maintenance
in "SERV" position.
jumper
in "SERV"
10
position
Connect the primary
The jumper in "SERV" position
power source (Mains
initialize the auto-enrolment of
230V~ ±10%, 50/60 Hz).
the peripherals automatically
at 10 seconds intervals.
11
Connect the
backup battery.
MAINS
CONNECTION
12
SmartLiving505
Set the addresses
SmartLiving515
of the peripherals.
terminal board
13
13
Start the quick
Autoacquisizione del
Programming wizard.
bilanciamento delle zone
dal Menù Installatore
230V~
230V~
14
Acquire automatically
This procedure allows you to skip the
the zone balancing
following steps and end with the step
via the installer menu.
otherwise continue with
the following steps.
15
Configure "Wireless"
13

terminals.

P R O G R A M M I N G
P a n e l o p t i o n s
16
T e r m i n a l s
Z o n e s
Edit the voice and
O u t p u t s
digital dialer contact
W a l k t e s t
numbers.
T e l e p h o n e
. . .
. . .
17
D e f a u l t s e t t i n g s
Insert the
U s e r f u n c t i o n s
maintenance jumper
O t h e r p a r a m e t e r s
W i z a r d
in "RUN" position.
Attention!
BALANCING
RESISTORS
Red
White
Orange
I-BUS
+ D S -
nBy/X-S
CONNECTION
reader
2
3K9
Red
Grey
Blue
3
SmartLiving
6K8
Control Panel
For SmartLiving G3 models,
use terminals
NO NC COM
"+ D S -" on the
10 11 12
+AUX
LIVPWR100
Generic
device
board
SmartLiving
Power supply
control panel
MAX 13.8V
X
6
X
External
device
8
SmartLogos30M
SmartLiving515
Battery
connector
connector
control panel PCB
SmartLiving1050L
Sm artLiving10100
power supply
power supply
SmartLiving1050
AC Input
AC Input
power supply
230V ~ 50/60 Hz
230V ~ 50/60 Hz
L
N
N L
230V~
10
230V~
,
17
Before starting the auto-learning phase
D e f a u l t s e t t i n g s
14
F a c t o r y d a t a
L e a r n z o n e b a l .
A u t o e n r o l P e r i p h
T e r m i n a l s
1 2 3 4 5
15
E X P A N . 0 0 1 I I I I I
E x p a n s .
0 1 T 0 1
T e l e p h o n e
S e l e c t n u m b e r
16
S e l e c t n u m b e r
N U M B E R
N u m b e r o f r i n g s
N U M B E R
M a x . n u m . a t t e m p t s
N U M B E R
N.C. / N.O.
4
BALANCING
+AUX
X
SmartLiving
control panel
Gold
5
6K8Ω 1/4W
1/4W
Detector
Detector
Gold
1/4W
SIRENS
PHONE LINE
CONNECTION
CONNECTION
SmartLiving
control panel
150Vrms
varistors
Self-powered
sounder
Interior
sounder
11
12
During the addressing phase, DO NOT exceed
the maximum number of addresses available
for the control panel model you are installing.
Battery
wires
Expansion -
DIP-switch
Transceiver
12345678
address
1
00000000
2
00000001
3
00000010
4
00000011
5
00000100
For SmartLiving 10100L
6
00000101
and G3 models, the
7
00000110
battery wire must
8
00000111
9
00001000
be connected on
10
00001001
the power supply
11
00001010
12
00001011
13
00001100
k e y p a d a d d r e s s
14
00001101
_ 1
15
00001110
M i n . 0 1
16
00001111
M a x . 3 0
17
00010000
18
00010001
19
00010010
20
00010011
21
00010100
22
00010101
23
00010110
24
00010111
25
00011000
12
26
00011001
Press together
27
00011010
and release
28
00011011
29
00011100
30
00011101
31
00011110
of the zone balancing parameters,
32
00011111
ensure that all zones are
33
00100000
in standby status.
34
00100001
Double terminals are not
35
00100010
enrolled properly.
36
00100011
37
00100100
T e r m i n a l s
1 2 3 4 5
38
00100101
E X P A N . 0 0 1 I I I I I
39
00100110
E x p a n s .
0 1 T 0 1
40
00100111
W i r e l e s s
Default
1,2,3,4,5,6 voice numbers for users
N U M B E R
y y y
7,8 CONTACT-ID
x x x
N u m b e r

telephone

9 voice number for the installer
y y y
D e s c r i p t i o n
numbers:
z z z
T y p e
15 teleservice
SINGLE
DOUBLE
BALANCING
BALANCING
SmartLiving
control panel
+AUX
X
SmartLiving
control panel
Detector
6K8Ω 1/4W
DOUBLE ZONE
7
1 2 3 4 5
BALANCING
SmartLiving
control panel
SmartLink
telephone
dialler
Zone1
3K9Ω 1/4W
Zone2
PSTN
network
6K8Ω 1/4W
Reader
Keypad
Red Blue Green Yellow
nBy/S
nBy/X
address
address
1
0
0
0
1
1
2
0
0
1
0
3
0
0
1
1
2
4
0
1
0
0
5
0
1
0
1
3
6
0
1
1
0
7
0
1
1
1
4
8
1
0
0
0
9
1
0
0
1
5
10
1
0
1
0
11
1
0
1
1
6
12
1
1
0
0
13
1
1
0
1
7
14
1
1
1
0
15
1
1
1
1
8
16
0
0
0
L
17
0
0
L
0
9
18
0
0
L
L
19
0
L
0
0
10
20
0
L
0
L
21
0
L
L
0
11
22
0
L
L
L
23
L
0
0
0
12
24
L
0
0
L
25
L
0
L
0
13
26
L
0
L
L
27
L
L
0
0
14
28
L
L
0
L
29
L
L
L
0
15
30
L
L
L
L
SmartLiving
0
LED OFF
Anti-intrusion control panels and security systems
1
LED ON
Installation and programming guide
L
LED blinking
For the readers
addressing,
use keypad
ISO 9001 Quality Management
"1"
certified by BSI with certificate
number FM530352
via Fosso Antico - fraz. Centobuchi
63076 Monteprandone (AP) ITALY
Tel. +39 0735 705007
Fax +39 0735 704912
info@inim.biz _
www.inim.biz
N.C. BALANCING
+AUX
X
WITH EOL
X
SmartLiving
control panel
3K9Ω 1/4W
Rollerblind/Shock
detector
SmartLiving
DOUBLE ZONE
SmartLiving
control panel
control panel
BALANCING
+AUX
+AUX
WITH EOL
X
X
Zone1
3K9Ω 1/4W
Zone2
6K8Ω 1/4W
EN 50131-1
EN 50131-3
EN 50131-6
EN 50136-1
EN 50136-2
EN 50130-4
EN 50130-5
CEI 79-2
CEB T014

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SmartLiving 505 and is the answer not in the manual?

Questions and answers

Summary of Contents for INIM SmartLiving 505

  • Page 1 M a x . n u m . a t t e m p t s N U M B E R z z z T y p e 15 teleservice in “RUN” position. Fax +39 0735 704912 info@inim.biz _ www.inim.biz...
  • Page 2 P a n e l o p t i o n s T e r m i n a l s 1 2 3 4 5 Z O N E n . x Z O N E n . x QUICK GUIDE TO CONTROL PANEL PCB TERMINAL BOARD 1.

Table of Contents