Start-up

Configuration

To configure the operation of the MTAC-01 module:
1. Power up the drive.
2. Use the control panel on the drive or the DriveWindow Light
PC tool and set group
page 21.
Encoder operating data
The following actual signals, based on measurements or
calculations, provide feedback from the encoder. You cannot set
these values directly, but you can use group
parameters to control the mechanical angle and revolution data.
No.
Name/Value

01 OPERATING DATA

0146 MECH ANGLE
0147 MECH REVS
0148 Z PLS
DETECTED
1)
Fieldbus equivalent, scaling between the value and the integer used in serial communication.
Start-up
50 ENCODER
Description
Calculated mechanical angle
Mechanical revolutions, i.e. the motor shaft
revolutions calculated by the encoder
Encoder zero pulse detector. 0 = not detected,
1 = detected
parameters described on
50 ENCODER
1)
FbEq
1 = 1
1 = 1
1 = 1