The following chart shows fan performance for the GP Series Fan:
1.0"
GP501
95
GP401
93
GP301
92
GP201
82
GP501
GP401
GP301
GP201
GP501
GP401
GP301
GP201
Inlet/Outlet: 3.5" OD (3.0" PVC Sched 40 size compatible)
Mounting: Fan may be mounted on the duct pipe or with integral flanges.
Weight: 12 lbs.
Size: 13H" x 12.5" x 12.5"
Recommended ducting: 3" or 4" Schedule 20/40 PVC Pipe
Storage temperature range: 32 - 100 degrees F.
Normal operating temperature range: -20 - 120 degrees F.
Maximum inlet air temperature: 80 degrees F.
Continuous Duty
Class B Insulation
3000 RPM
Thermally Protected
Rated for Indoor or Outdoor Use
Page 7 of 8
GP SERIES PRODUCT SPECIFICATIONS
Typical CFM Vs Static Suction "WC
1.5"
2.0"
87
80
82
60
77
45
58
5
Maximum Recommended Operating Pressure*
3.8" W.C.
3.0" W.C.
2.4" W.C.
1.8" W.C.
Power Consumption @ 120 VAC
70 - 140 watts
60 - 110 watts
55 - 90 watts
40 - 60 watts
2.5"
3.0"
3.5"
70
57
30
38
12
-
10
-
-
-
-
-
(Sea Level Operation)**
(Sea Level Operation)**
(Sea Level Operation)**
(Sea Level Operation)**
*Reduce by 10% for High Temperature Operation
**Reduce by 4% per 1000 feet of altitude