  • Page 1 SF180 Installation Instructions IN065 Rev F 0118 3 Saber Way, Ward Hill, MA 01835 | radonaway.com...
  • Page 2 If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit. RadonAway SF Series Fan Wiring Diagram IN065 Rev F 0118 3 Saber Way, Ward Hill, MA 01835 | radonaway.com...
  • Page 3: System Design Considerations

    In the event that a temporary high water table results in water at or above slab level, water may be drawn into the riser pipes thus blocking air flow to the SF180. The lack of cooling air may result in the fan cycling on and off as the internal temperature rises above the thermal cutoff and falls upon shutoff.
  • Page 4: Condensation & Drainage

    1.9 SPEED CONTROLS The SF180 Radon Fan is rated for use with electronic speed controls. The recommended speed control if used is Pass & Seymour Solid State Speed Control Cat. No. 94601-I.
  • Page 5: Installation

    2.0 INSTALLATION The SF180 can be mounted indoors or outdoors. (It is suggested that EPA recommendations be followed in choosing the fan location.) The SF Series Fan is intended be mounted directly on the system piping. There is no mounting bracket available for this unit. In addition to the inlet and outlet...
  • Page 6 8.5”H x 9.7” Dia. 5.5 lbs 4.5”OD (4.0” PVC Sched 40 size compatible) Recommended ducting: 3” or 4” SF180, Schedule 20/40 PVC Pipe (Sch.40 preferred) Mounting: Mount on the duct pipe. Storage temperature range: 32 - 100 degrees F. Thermal Cutout: SF180: 150ºC / 302ºF...
  • Page 7 THE EXTENT THE SAME DOES NOT MEET WITH RADONAWAY’S WARRANTY AS PROVIDED ABOVE. For service under this Warranty, contact RadonAway for a Return Material Authorization (RMA) number and shipping information. No returns can be accepted without an RMA. If factory return is required, the customer assumes all shipping costs, including insurance, to and from factory.