The following chart shows fan performance for the XP & XR Series Fan:
0"
.25"
XP101
125
118
XP151
180
162
XP201
150
130
XR261
250
215
XP101
XP151
XP201
XR261
XP101
XP151
XP201
XR261
XP Series Inlet/Outlet: 4.5" OD (4.0" PVC Sched 40 size compatible)
XR Series Inlet/Outlet: 5.875" OD
Mounting: Mount on the duct pipe or with optional mounting bracket.
Recommended ducting: 3" or 4" Schedule 20/40 PVC Pipe
Storage temperature range: 32 - 100 degrees F.
Normal operating temperature range: -20 - 120 degrees F.
Maximum inlet air temperature: 80 degrees F.
Size: 9.5H" x 8.5" Dia.
Weight: 6 lbs. (XR261 - 7 lbs)
Continuous Duty
Thermally Protected
Class B Insulation
3000 RPM
Rated for Indoor or Outdoor Use
Page 6 of 8
XP/XR SERIES PRODUCT SPECIFICATIONS
Typical CFM Vs Static Suction "WC
.5"
.75"
90
56
140
117
110
93
185
150
Maximum Recommended Operating Pressure*
0.9" W.C.
1.3" W.C.
1.7" W.C.
1.6" W.C.
Power Consumption @ 120 VAC
40 - 49 watts
45 - 60 watts
45 - 66 watts
65 - 105 watts
1.0"
1.25"
1.5"
5
-
-
78
46
10
74
57
38
115
80
50
(Sea Level Operation)**
(Sea Level Operation)**
(Sea Level Operation)**
(Sea Level Operation)**
*Reduce by 10% for High Temperature Operation
**Reduce by 4% per 1000 feet of altitude
1.75"
2.0"
-
-
-
-
20
-
20
-