RadonAway RP SERIES Installation Instructions Manual

Advertisement

Quick Links

IN020 Rev F
Page 1 of 8

Advertisement

Table of Contents
loading

Summary of Contents for RadonAway RP SERIES

  • Page 1 IN020 Rev F Page 1 of 8...
  • Page 2 RadonAway Ward Hill, MA. Series Fan Installation Instructions Please Read and Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL SERVICE TO FAN IS LOCKED IN "OFF" POSITION. DISCONNECT POWER BEFORE SERVICING FAN.
  • Page 3 In the event that a temporary high water table results in water at or above slab level, water may be drawn into the riser pipes thus blocking air flow to the RP Series Fan. The lack of cooling air may result in the fan cycling on and off as the internal temperature rises above the thermal cutoff and falls upon shutoff.
  • Page 4: Condensation & Drainage

    The system design must provide a means for water to drain back to a slab hole to remove the condensation. The RP Series Fan MUST be mounted vertically plumb and level, with the outlet pointing up for proper drainage through the fan. Avoid mounting the fan in any orientation that will allow water to accumulate inside the fan housing.
  • Page 5: Electrical Wiring

    8 ELECTRICAL WIRING The RP Series Fans operate on standard 120V 60 Hz. AC. All wiring must be performed in accordance with the National Electrical Code and state and local building codes. All electrical work should be performed by a qualified electrician. Outdoor installations require the use of a U.L.
  • Page 6: System Piping

    2.6 OPERATION CHECKS _____ Verify all connections are tight and leak-free. _____ Insure the RP Series Fan and all ducting is secure and vibration-free. _____ Verify system vacuum pressure with manometer. Insure vacuum pressure is less than maximum recommended operating pressure (Based on sea-level operation, at higher altitudes reduce by about 4% per 1000 Feet.)
  • Page 7 RP SERIES PRODUCT SPECIFICATIONS The following chart shows fan performance for the RP Series Fan: Typical CFM Vs Static Pressure "WC 0" .25" .5" .75" 1.0" 1.25" 1.5" 1.75" 2.0" RP140 RP145 RP155 RP260 RP265 RP380* * Tested with 6” inlet and discharge pipe.
  • Page 8 5 YEAR EXTENDED WARRANTY WITH PROFESSIONAL INSTALLATION. RadonAway will extend the Warranty Term of the fan to 5 years from date of manufacture if the Fan is installed in a professionally designed and professionally installed radon system or installed as a replacement fan in a professionally designed and professionally installed radon system.

This manual is also suitable for:

Dunavac rp140Dunavac rp155Dunavac rp145Dunavac rp260Dunavac rp265Dunavac rp380