Summary of Contents for RadonAway HS Series

  • Page 1 The World’s Leading Radon Fan Manufaturer HS Series Installation & Operating Instructions RadonAway 3 Saber Way Ward Hill, MA 01835 www.radonaway.com P/N IN007-REV J 9/13...
  • Page 2 2. WARNING! Do not use fan to pump explosive or corrosive gases. See Vapor Intrusion Application Note #AN001 for important information on VI applications. RadonAway.com/vapor-intrusion 3. WARNING! Check voltage at the fan to insure it corresponds with nameplate.
  • Page 3: System Design Considerations

    104 degrees F. Thus if the HS Series Fan is idle in an area where the ambient temperature exceeds this shut off, it will not restart until the internal temperature falls below 104 degrees F.
  • Page 4: Condensation & Drainage

    Under no circumstances should water be allowed to be drawn into the inlet of the HS Series Fan as this may result in damage to the unit. The HS Series Fan should be mounted at least 5 feet above the slab penetration to minimize the risk of filling the HS Series Fan with water in installations with occasional high water tables.
  • Page 5: Electrical Wiring

    1.7 SLAB COVERAGE The HS Series Fan can provide coverage of well over 1000 sq. ft. per slab penetration. This will, of course, depend on the sub-slab aggregate in any particular installation and the diagnostic results. In general, sand and gravel are much looser aggregates than dirt and clay.
  • Page 6: Installation

    2.1 MOUNTING Mount the HS Series Fan to the wall studs, or similar structure, in the selected location with (4) 1/4" x 1 1/2" lag screws (not provided). Insure the HS Series Fan is both plumb and level. 2.2 DUCTING CONNECTIONS Make final ducting connection to HS Series Fan with flexible couplings.
  • Page 7: Product Specifications

    Addendum PRODUCT SPECIFICATIONS *Power consumption varies with actual load conditions Inlet: 3.0" PVC Outlet: 2.0" PVC Mounting: Brackets for vertical mount Weight: Approximately 18 lbs. Size: Approximately 15"W x 13"H x 8"D Minimum recommended inlet ducting (greater diameter may always be used ): HS3000, HS5000 --- 2.0"...
  • Page 8 RadonAway will repair any fan which fails due to defects in materials or workmanship. The Fan must be returned (at owner’s cost) to the RadonAway factory. Proof of purchase must be supplied upon request for service under this Warranty.