  • Page 2 RadonAway Ward Hill, MA. Series Fan Installation Instructions Please Read and Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL SERVICE TO FAN IS LOCKED IN "OFF" POSITION. DISCONNECT POWER BEFORE SERVICING FAN.
  • Page 3: System Design Considerations

    For installations in an area of severe cold weather, please contact RadonAway for assistance. When not in operation, the fan should be stored in an area where the temperature is never less than 32 degrees F. or more than 100 degrees F.
  • Page 4: Condensation & Drainage

    1.6 CONDENSATION & DRAINAGE Condensation is formed in the piping of a mitigation system when the air in the piping is chilled below its dew point. This can occur at points where the system piping goes through unheated space such as an attic, garage or outside.
  • Page 5: Installation

    2.0 INSTALLATION The SF Series Fan can be mounted indoors or outdoors. (It is suggested that EPA recommendations be followed in choosing the fan location.) The SF Series Fan is intended be mounted directly on the system piping. There is no mounting bracket available for this unit. In addition to the inlet and outlet pipe mounts a single vibration mount is provided at the bottom right hand corner of the inner housing, underneath the removeable corner cover, the vibration mount may be screwed directly to the house siding.
  • Page 6: System Piping

    2.1 MOUNTING Mount the SF Series Fan vertically with outlet up. Insure the unit is plumb and level. When mounting directly on the system piping assure that the fan body does not contact any building surface to avoid vibration noise. 2.2 SYSTEM PIPING Complete piping run, using flexible couplings as means of disconnect for servicing the unit and vibration isolation.
  • Page 7 17.5H”x16W”x6.5D” 13.1 lbs. 4.5" OD (4.0" PVC Sched 40 size compatible) Recommended ducting: 3" or 4" SF180, , Schedule 20/40 PVC Pipe (Sch.40 prefered) Mounting: Mount on the duct pipe. Storage temperature range: 32 - 100 degrees F. Normal operating temperature range: -20 - 120 degrees F.
  • Page 8 90 days from the date of purc has e (the “W arranty Term”). RadonAway will repl ac e any F an which fails due to defec ts in materials or workm anship. The F an must be returned (at Owner’s c os t) to the RadonAway factory .