1.
Control
The capacity of the system and the network address of the air-conditioner can be set by the switches on
the Main Control Board of the indoor unit.
After the setting, be sure to cut down the main power supply switch, then turn it on again.
Setting would be invalid without disconnecting the power.
1.1 Horsepower code set
The capacity of the indoor unit has been set before leaving the factory according to the below table.
NC1
Note: The capacity has been set before leaving the
factory, anyone can't modify it except the maintenance
person.
1.2 Network address set
Every air-conditioner in network has only one network address to distinguish each other. Address code of
air-conditioner in LAN is set by code switches S1 & S2 on the Main Control Board of the indoor unit, and the
set range is 0-63.
S1
Toggle switch set
S2
Toggle switch Code
4
5
7
8
9
9
Network address code
Capacity(Btu/h)
18000
24000
30000
36000
48000
60000
00~15
16~31
32~47
48~63