Setting Parameters For Reliable Performance Using Acoustic Drum Triggers And Other Manufacturers' Pads (Advanced Trigger Parameters) - Roland SPD-20 Owner's Manual

Total percussion pad
Hide thumbs Also See for SPD-20:
Table of Contents

Advertisement

Setting Parameters for Reliable Performance using Acoustic Drum
Triggers and Other Manufacturers' Pads
Sometimes, when you use the SPD-20 with an acoustic drum trigger or a pad from another manufacturer,
setting only the Trigger Type may result in poor sound or mistakenly played sounds. In such cases, by set-
ting the Advanced Trigger Parameters, you can make more detailed trigger parameter settings.
Advanced Trigger Parameters are set automatically when the Trigger Type is set. Normally, when
NOTE
you set the Trigger Type, no setting of the Advanced Trigger Parameters is necessary.
The five Advanced Trigger Parameters are as follows:
Scan Time
Retrigger Cancel
Mask Time
Crosstalk Cancel
Rim Sensitivity
How to Set Advanced Trigger Parameters
The process of making settings for the Advanced Trigger Parameters differs from that when making
other settings. Special procedures are required to set the parameters in Advanced Edit mode.
The Advanced Trigger Parameters cannot be found in the Parameter List on the front panel.
NOTE
You cannot make Advanced Trigger Parameter settings for internal pads.
There are three modes
Play mode:
Edit mode:
Advanced Edit mode:
First, set the Trigger Type. When you set the Trigger Type, the most suitable Advanced Trigger
Parameters values are set automatically.
If, after having set the Advanced Trigger Parameters, you then change the Trigger Type setting, the
NOTE
Advanced Trigger Parameter settings revert to the initial values for that Trigger Type.
1
2
3
fig. 57
48
Sets the time for detecting the trigger signal
Detects the attenuation of the trigger signal, and prevents subsequent
incorrect triggering
Prevents secondary sounding of the kick pad and other pads
Prevents triggering caused by vibration from other pads
Adjusts the sensitivity of the PD-120´s rim
The unit is played in this mode.
Status in which settings are made for the parameters from the parameter
list.
In this mode, settings can be made for the Advanced Trigger Parameters,
which are not included in the parameter list.
In Edit mode, select the SYSTEM parameter group (p. 21).
Press [
] or [
] to select the TRIG TYPE.
Strike the external pad (or drum pad) to be set.
(Advanced Trigger Parameters)