2.3.6 Alive Check
The GSW 802.3at PoE+ Switch series can be configured to monitor connected PD's
status in realtime via traffic detection. Once there is no traffic at interval time, the
GSW 802.3at PoE+ Switch series is going to restart PoE port power, and bring the
PD back to work. It will greatly enhance the reliability and reduce administrator
management burden.
Object
Port
Select the port number to enable Alive Check.
Allows user to enable or disable per port PD Alive Check
Status
function. All ports are disabled as default value.
PD startup time.
Startup Time
This startup time is based on determining when to start to
(60~300s)
measure the traffic. The default startup time is 180 seconds.
Traffic detection counter.
Interval Time
The switch detects no traffic during this time and countdown
(60~300s)
for interval time begins and port begins to reboot. The default
interval time is 180 seconds.
PoE Port Disable Timer
Power Off
This column allows user to set the PoE device rebooting time.
(5~60s)
The default power off time is 5 seconds.
PD Traffic=0
PD ready
0
Startup
Startup
180
Figure 2-4: Alive Check Mechanism
Description
Interval Time
Countdown
PD Halt
Power
No traffic!
450
Interval
Power
OFF
ON
Time(s)
630
635
Power OFF
23