Supermicro FatTwin F617H6-FTL+ User Manual page 80

Dual processor high-end server
Table of Contents

Advertisement

FatTwin F617H6-FTL+/FTPTL+ User's Manual
HDD Activity LED
An HDD Activity LED is located at
HDD_ACT_LED1 on the motherboard.
When the HDD LED is blinking, an HDD
device is active. See the table at right for
more information.
BMC Heartbeat LED
A BMC Heartbeat LED is located at
BMC_HB_LED1 on the motherboard.
When this LED indicator is blinking,
BMC is normal. See the table at right
for more information.
SAS Heartbeat LED
A SAS Heartbeat LED is located at
SAS_HB_LED1 on the motherboard.
When LEDS2 is blinking, SAS is working
properly.
Failure LED
A BMC Failure LED is located at
Failure_ LED1 on the motherboard.
When this LED indicator is on, BMC is
not working properly. See the table at
right for more information.
UID LED
The Unit Identifi er (UID) LED is located
at UID_ LED1 on the motherboard.
When this LED is on, the unit that might
be in need of service is identifi ed. See
the table at right for more information.
HDD Activity LED
(HDD_ACT_LED1)
Color or State
Green: Blinking
Off
BMC Heartbeat (BMC_HB_LED1)
Color/State
Green: Blinking
Steady On
SAS Heartbeat LED
(SAS_HB_LED1)
Color/State
Green: Blinking
Off or Red
(Failure_LED1)
State
On
Color/State
Blue: On
5-26
Status
Defi nition
HDD: Active
HDD Disabled, or Failed
LED Status
Defi nition
BMC: Normal
BMC Disabled, or
Failed
Status
Defi nition
SAS: Normal
SAS: Disabled or Failed
Failure LED
Status
Defi nition
BMC: Failed
Rear UID LED
(UID_LED1)
Status
Defi nition
Unit Identifi ed

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fattwin f617h6-ftptl+

Table of Contents