3.2

Advanced functions, Manuel reset

In case of exchanged parts (i.e. motor, electronics) there could be a need of a manual
reset so columns and handsets correspond to each other. Even poor connection of the
cables could create a need of resetting.
>7 sec
1. Press both buttons
CAUTION
Risk of pinching.
4.
MAINTENANCE & REPAIRS
4.1

Cleaning, Inspection and Storage

Clean the table frame by wiping it down with a microfiber cloth. Never use solvent or
abrasive or corrosive compounds.
Products must be cleaned at regular intervals to remove dust and dirt and inspected for
mechanical damage and normal wear and tear. Worn-out parts must be replaced. Unplug
the power cord if you do not intend to use the desk for a longer period.
4.2

User Maintenance

Products are closed units and require no internal maintenance.
Columns must be inspected at attachment points, wires, piston rod, cabinet, and plugs,
check that columns function correctly.
Inspect columns for loose connections and damaged plugs/wires.
Inspect power supply for loose connections and damaged plugs/wires.
The power supply and the handset is sealed and maintenance free.
4.3

Repairs

Check all screws and bolts after the first week of use and tighten screws and bolts where
necessary to ensure safe operation of the table.
String Furniture AB
2. Drive the columns
down to lowest level
3. Ready to use
www.string.se
info@string.se