② SOC Limit
  You can assign the lower limit of battery SOC. Battery will stop discharging when its SOC
  reach this limit.
③ Peak Cut Power
  Peak cut power is used in peak cut mode. You can assign the peak power of home load
  usage from grid. When the home load consumption exceeds this value, battery will discharge
  to supply remaining power.
④ Time Settings
  Time settings can be separated into BT charge time and BT discharge time.
  Each setting can set 3 time intervals. These 6 time intervals cannot overlap with each other.
  When the inverter operation mode set to self-consumption or selling first mode, time settings
  is enabled. Hybrid inverter will automatically change the mode to charge first / discharge first
  in the time intervals you set and return to self-consumption / selling first mode outside the
  intervals.
 A change is confirmed.
 * None of the settings will change until the "Save" button is touched at the end. Caution is required.
 Touch
to turn off the dialog box.
  A screen in which the desired Inverter can be selected
  is displayed.
  Touch the button to display the Inverter Selection dialog
  box. Touch the No. of the desired Inverter.
  Change the display to the Home screen.
  Touching this button to display another page menu.
  Touch the desired page to switch the display to the desired screen.
  Grid Setting can be verified.
  Refer to "Grid Setting" (Page 67) for details.
  Sleep time ,brightness, slideshow and language for the screen can
  be set. Refer to "Screen Setting" (Page 68) for details.
Operating method
・In the Home screen, touch
・Use
→  
to switch each screen.
81
What Power Monitor can do
.