Download Print this page
Watts 654 Quick Setup Manual

Watts 654 Quick Setup Manual

Snow melting control

Advertisement

Quick Links

Quick Set-up Guide
Snow Melting Control 654
1.
Location
Behind
Door
Exterior
Wall
3.
Install Mounting Base
Front
Base
3
(83 mm)
5.
Wiring
Transformer
R
L
N
C
Relay
3
2
4
1
8
5
+
T
T
6
7
Modulating
Boiler
Interior
5 feet
1.5 m
Stud
Base
Front
1
/
"
4
Gang
Box
Optional
tN4
Communication
C tN4
Relay
3
2
4
1
8
5
6
7
System
Pump
G
n
L
5 V (ac)
2.
Wall
4.
Stud
Wall
No Power
Aux Ht
R
C
tN4
Mod
Brn
Yel Blu Red
Blk
+
Slab
Com
 of 2
Remove Mounting Base
Switch Settings
LoCk ACCESS LEvEL
1058-04
The control is locally locked and the access
Snow Melting Control 654
ON
level cannot be changed. Set to Lock when
Order #81016552
 2
www.WattsRadiant.com
installation has been completed.
Power: 24 V (ac) ±10%, 60 Hz, Class 2,
16 VA standby, 100 VA fully loaded
UnLoCk ACCESS LEvEL
Relays: 24 V (ac) 2 A, 3.5 A combined
Designed and assembled in Canada
The control is unlocked and the access
Back of
Meets Class B: ICES & FCC Part 15
H1226A
level may be changed. Go to the Toolbox
Control
menu to change the access level. Set to
Unlock during the installation process.
Snow / Ice
Sensor 090
Or
Brn
Yel Blu Red
Blk
Slab
Com
Out/
Sup
Bret
Supply
Outdoor
Sensor
Sensor
082
070
Snow
Slab
Sensor 095
Sensor 072
And/Or
Snow
Sensor
095
Brn
Yel Blu Red
Blk
Slab
Com
© 203 Watts Radiant

Advertisement

loading

Summary of Contents for Watts 654

  • Page 1 Quick Set-up Guide Snow Melting Control 654 Location Remove Mounting Base Interior Wall Behind Door 5 feet 1.5 m Exterior Wall Install Mounting Base Switch Settings LoCk ACCESS LEvEL 1058-04 Stud The control is locally locked and the access Snow Melting Control 654 Front Base Stud Base level cannot be changed. Set to Lock when...
  • Page 2 System Control should operate ® Default = 090 when the snow melt zone is heating. SLAB SEnSoR Conditions: Application Mode is set to PWM, Boil or Mix and Boiler Type is set to CTRL Select if a Slab Sensor 072 is installed to (tN4 control). measure the slab temperature. Default = ON Default = ON AUxILIARy RELAy SLAB PRoTECTIon Select if the auxiliary relay should function Select if the slab should be protected from large as system pump or as an alert. temperature differentials to avoid cracking the Default = SYS concrete due to high tensile stress. Default = ON MAxIMUM MELT TIME Select to limit the amount of melting run time. Default = 3.0 days A Watts Water Technologies Company USA: Springfield, MO • Tel. (800) 276-249 • Fax: (47) 864-86 • www.wattsradiant.com Canada: Burlington, ONT. • Tel. (905) 332-4090 • Fax: (905) 332-7068 • www.watts.ca IS-WR-Snow_Melting_Control-654 328 © 203 Watts Radiant...