Watts HF Scientific Air Sentinel III Manual

Watts HF Scientific Air Sentinel III Manual

Advertisement

Installation Instructions
Air Sentinel III
Purge Controller - Model 110046

Table of Contents

Understanding Safety Information .......................................................2
Declaration of Conformity ...................................................................3
Introduction to the Unit .......................................................................4
Overview.........................................................................................4
Use in Explosive Environments Safely .............................................4
Specifi cations .................................................................................4
Instrument Labels ...........................................................................4
Orientation ......................................................................................4
Dimensions .....................................................................................4
Installation and Commissioning ...........................................................5
Air Supply .......................................................................................5
Electrical Power Input Connections .................................................5
Electrical Power Output Connections ..............................................5
Electrical Alarm Connections ..........................................................5
Mechanical Mounting ......................................................................5
Operation ...........................................................................................6
Startup ...........................................................................................6
Indicator Lamps ..............................................................................6
Maintenance Bypass Operation ......................................................6
Programming ......................................................................................6
Warranty .............................................................................................7
IS-HF-AirSentinelIII-100123 Rev 0 2020-09

Advertisement

Table of Contents
loading

Summary of Contents for Watts HF Scientific Air Sentinel III

  • Page 1: Table Of Contents

    Installation Instructions Air Sentinel III Purge Controller - Model 110046 Table of Contents Understanding Safety Information ............2 Declaration of Conformity ..............3 Introduction to the Unit ...............4 Overview..................4 Use in Explosive Environments Safely ..........4 Specifi cations .................4 Instrument Labels ................4 Orientation ..................4 Dimensions ..................4 Installation and Commissioning ............5 Air Supply ..................5...
  • Page 2: Understanding Safety Information

    Understanding Safety Information This manual contains safety and use instructions that must be followed during the installation, commissioning, operation, care and maintenance and service of the AccUView LED Ex. All responsible personnel must read this manual prior to working with this instrument and should familiarize themselves with the following safety symbols, signals and pictorials.
  • Page 3: Declaration Of Conformity

    Declaration of Conformity EX mb [pxb] IIC T4 Gb 0°C ≤ Ta ≤ 55°C IECEx Certificate #IECEx LC19.0014 To the following standards: Explosive Atmospheres - Part 0: Equipment - General Requirements, IEC 60076-0:2017 Explosive Atmospheres - Part 2: Equipment Protection by Pressurized Enclosure “p”, IEC 60079-2:2014 Explosive Atmospheres - Part 18: Equipment Protection by Encapsulation “m”, IEC 60079-18:2017 Emissions &...
  • Page 4: Introduction To The Unit

    Introduction to the Unit Instrument Labels Overview The following labels should be applied to the outside of the enclosure. The Air Sentinel III is a purge controller that can be used to provide protection for electrical equipment operating in potentially hazardous areas.
  • Page 5: Installation And Commissioning

    Installation and Commissioning Mechanical Mounting Air Supply The Air Sentinel III is mounted to an enclosure using the 10,1/4”- This instrument requires water free and oil free air, Dry Air, Particles <5u, 20 studs. The recommended hardware is a 1/4” flat washer and ISA Grade Hydrocarbon Free.
  • Page 6: Operation

    Operation Maintenance Bypass Operation The Air Sentinel III purge controller is mounted on the side of the main enclosure. This controller will ensure proper safe operation of DANGER the attached equipment. If all of the required conditions are met, the controller will act as a power governor.
  • Page 7: Warranty

    Warranty HF scientific, LLC (the “Company”) warrants each product to be free from defects in material and workmanship under normal usage for a period of two (2) years from first use or three (3) years from date of invoice, whichever occurs first. In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge.
  • Page 8 USA: T: (239) 337-2116 • Toll-Free (888) 203-7248 • F: (239) 332-7643 • HFscientific.com Latin America: T: (52) 81-1001-8600 • HFscientific.com 2020-09 IS-HF-AirSentinelIII-100123 Rev 0...

This manual is also suitable for:

110046

Table of Contents