1 Introduction to the NA-series Programmable Terminals
Item
International
*4
standards
*1. The ambient operating temperature is subject to the following restrictions, depending on the mounting angle.
• The ambient operating temperature is 0° to 40°C when the mounting angle is 0° or more and less than 45°
to the horizontal.
• The ambient operating temperature is 0° to 50°C when the mounting angle is 45° or more and 90° or less
to the horizontal.
• The ambient operating temperature is 0° to 50°C when the mounting angle is 90° or more and 135° or less
to the horizontal.
50°C
50°C
90° to 135°
*2. Use the PT within the following temperature and humidity ranges.
100
90
80
70
60
50
40
30
20
10
0
-10
1 - 8
NA5-15W
NA5-12W
NA5-15U
NA5-12U
UL 508/CSA standard C22.2 No.142
EMC Directive (2004/108/EC) EN 61131-2:2007
Shipbuilding standards LR, DNV, and NK
IP65 oil-proof, UL Type 4X (front panel only)
ANSI 12.12.01 Class 1 Division 2/CSA standard C22.2 No. 213-M1987 (R2013)
RoHS Directive (2002/95/EC)
KC Standards KN 61000-6-2:2012-06 for EMS and KN 61000-6-4:2012-06 for EMI
RCM
50°C
50°C
50°C
45° to 90°
40°C
0° to 45°
Operating
temperature-humidity
range
0
10
20
30
Temperature [°C]
Specification
NA5-9W
NA5-9U
*5
40°C
40
50