Mounting instructions

Ideally, mount SITRANS Probe LU so that the face of the transducer is at least
Note:
300 mm (1 ft) above the highest anticipated level.
SITRANS Probe LU is available in three thread types: 2" NPT, 2" BSP , or PF2/G (BS EN ISO 228-1).
1.
Before inserting SITRANS Probe LU into its mounting connection, ensure that the threads
are of the same type to avoid damaging them.
2.
Simply screw SITRANS Probe LU into the process connection and hand tighten.
Wiring
1
Power
WARNINGS:
DC terminals shall be supplied from an SELV
IEC-1010-1 Annex H.
All field wiring must have insulation suitable for rated voltages.

Connecting SITRANS Probe LU (PROFIBUS PA)

Note:
• For detailed wiring instructions, please see the full manual.
• For Intrinsically Safe setups (FM/CSA Class I, Div. 1), see
Connection Drawing
• For Non-Incendive setups (FM: Class I, Div. 2), see
on page 5 of Appendix A, for drawing number 23650583.
• The non-metallic enclosure does not provide a continuous ground path between conduit
connections: use grounding-type bushings and jumpers.
• Separate cables and conduits may be required to conform to standard instrumentation
wiring practices, or electrical codes.
1.
Strip the cable jacket for approximately
70 mm (2.75") from the end of the PROFIBUS PA
cable, and thread the wires through the gland
2.
Connect the wires to the terminal as shown:
Probe LU (PROFIBUS PA) is not polarity-sensitive.
1.
Safety Extra Low Voltage
2.
If cable is routed through conduit, use only approved suitable-size hubs for waterproof applications.