Carrier Ultra Operator's Manual page 26

Trailer refrigeration units with standard microprocessors, beginning with s/n har90573670
Table of Contents

Advertisement

The following table has columns for Code and English displays.
English is the default setting. Change Functional Parameter to
Code to see Code display format.
CODE
ENGLISH
AL0
ENG OIL
AL1
ENG HOT
AL2
HI PRESS
AL3
STARTFAIL
AL4
LOW BATT
AL5
HI BATT
AL6
DEFR FAIL
AL7
ALT AUX
AL8
STARTER
AL9
RA SENSOR
AL10
SA SENSOR Supply Air Sensor
WT SENSOR Coolant Temperature
AL11
AL12
HIGH CDT
CD SENSOR Compressor Discharge
AL13
AL14
SBY MOTOR Standby Motor Overload
AL15
FUSE BAD
AL16
SYSTEM CK
AL17
DISPLAY
AL18
SERVICE 1
AL19
SERVICE 2
AL20
OUT RANGE
= FAULT LIGHT ON
Display
ALARM DESCRIPTION
Low Oil Pressure
High Coolant
Temperature
High Pressure
Auto Start Failure
Low Battery Voltage
High Battery Voltage
Defrost Override
Alternator Not Charging
Starter Motor
Return Air Sensor
Sensor
High Discharge
Temperature
Temperature Sensor
(NDM Only)
Fuse Blown Or Dirty
Battery Cables
Check Refrigeration
System
Display
Maintenance Hour Meter 1
Maintenance Hour Meter 2
Out-of-range
23
62--10601

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SolaraExtra xtUltra xl

Table of Contents